3.4 - Scan Response Data
Item
Data
Detail
Complete local name
RemoteG10
3.5 - Un-Pairing mode
a) Un-pairing from the STB clears Remote Control bonding cache.
b) Remove Device bonding cache (manual approach - Optional):
Press and hold [BACK] key while inserting batteris.
3.6 - Connection Parameter (TBD)
a) Connection Interval Time: ms
b) Connection Slave Latency: (sec)
c) Connection Supervision Time Out: sec
3.7 - Reconnection
a) Upon an unexpected disconnect from the STB, the Remote Control shall automatically
attempt to reconnect to the STB.
b) It is recommended that the Remote Control uses an aggressive advertising interval (ex.
20ms) for the first 30-60 seconds after being disconnected. The Remote Control may
then switch to a more battery friendly advertising interval if the connection was not re-
established after 30~60 seconds. The Remote Control may stop attempting to connect
after a 2mins interval if no user intraction (ex. Button press) has been detected.
c) If the Remote Control is not connected and the user initiates the Remote Control wake-
up and connection by pressing a button on the Remote Control, the Remote Control
shall cache the button press event and forward it to the STB after successfully
establishing a connection.
d) If a button event is cached and being held until the connection is established, any further
key presses may be discarded until the cached event is successfully passed to the STB.
3.8 - Key codes for STB
a) In Bluetooth mode, HID Profile is used.