User's Manual

OCS SMART _ USER MANUAL _ VERSION 1.00 OJMAR 38
cover.
NOTE: Use a Torx TX10 screwdriver.
2. Remove the battery holder.
3. Replace the four AA alkaline batteries.
4. Insert the battery holder.
5. Put the cover on and tighten the screws.
NOTE: *The lock will keep the time and date for a maximum of 20 seconds after
removing the batteries; if this time is exceeded the lock has to be re-initialised.
Battery replacement
Battery holder
WARNING: Risk of explosion if battery is replaced with a battery of the wrong
kind. Dispose of batteries in accordance with the instructions.
4.7 EMERGENCY OPENING
The lock can be powered externally if a battery is faulty and the lock does not have any
power.
In these circumstances a 9V 6LR61 battery must be placed on the contacts located at the
bottom of the front. The connection has to be done manually so that the + pole of the
battery is on the right and the on the left. When the battery is correctly placed in the
contacts, the lock will turn on and can be used normally using either the keypad or the app.
NOTE: The emergency opening of OCS locks with a handle must be done with a
special tool. Should this be the case, contact OJMAR Intelligent locking systems.