Operation Manual
Troubleshooting > 159
cavity area. Then allow the pressure release lever to
rise again.
9. Starting with the cyan image drum unit nearest the fuser,
replace the four image drums into the drum cavity,
making sure to locate them in the correct order.
NOTE
If the sheet is well advanced into the fuser (only a short
length is still visible), do not attempt to pull it back. Follow the
next step to remove it from the rear of the MFP.
1
2
3
4
1. Cyan cartridge 2. Magenta cartridge
3. Yellow cartridge 4. Black cartridge