Operation Manual

Specifications (MB461/MB461+LP/MB471/MB471w/MB491/MB491+/MB491+LP/ES4161 MFP/ES4191 MFP/MPS4200mb/MPS4700mb)
-187-
Appendix
9
Media type
Standard paper (60 g/m
2
- 163 g/m
2
), envelopes, label.
Feeding method Automatic feeding
from the tray 1 and
tray 2 (optional),
Manual feeding from
Manual Feeder
Automatic feeding from the tray 1, MP tray
and tray 2 (optional), Automatic feeding
from MP tray
Automatic feeding
from the tray 1, MP
tray and tray 2
(optional), Automatic
feeding from MP tray
Paper loading
capacity
Tray 1
250 sheets of
Standard paper /80
g/m
2
, total thickness
25mm or lower.
Manual Feeder
1 sheet.
Tray 2 (optional)
530 sheets of
Standard paper /80
g/m
2
, total thickness
53 mm or lower.
Tray 1
250 sheets of Standard paper /80 g/m
2
,
total thickness 25mm or lower.
MP tray
100 sheets of Standard paper /80 g/m
2
and
total thickness 10mm or lower, 10
envelopes/ weight of 85 g/m
2
.
Tray 2 (optional)
530 sheets of Standard paper /80 g/m
2
,
total thickness 53 mm or lower.
Tray 1
250 sheets of
Standard paper /80
g/m
2
, total thickness
25mm or lower.
MP tray
100 sheets of
Standard paper /80
g/m
2
and total
thickness 10mm or
lower, 10 envelopes/
weight of 85 g/m
2
.
Tray 2 (optional)
530 sheets of
Standard paper /80
g/m
2
, total thickness
53 mm or lower.
Output method Face down
Paper output capacity Face down
150 sheets (less than 80 g/m
2
)
Print guaranteed area 6.35 mm or more from the paper edge (not applicable to special media such as
envelopes)
Print precision Print beginning:± 2 mm, paper skew: ± 1 mm/100 mm, image expansion: ± 1 mm/100
mm (80 g/m
2
)
Warm-up time From power on
Less than 60 seconds
From power save mode
Less than 25 seconds
Usage Environment
Conditions
When in operation
10~32°C / Relative Humidity of 20~80% (maximum wet bulb temperature of 25°C,
maximum dry bulb temperature of 2°C)
When not in operation
0~43°C / Relative Humidity of 10~90% (maximum wet bulb temperature of 26.8°C,
maximum dry bulb temperature of 2°C)
Conditions for the
guarantee of print
quality
Temperature 10°C, humidity 30 to 78% RH/ temperature 32°C, humidity 30 to 54% RH/
humidity 30% RH, temperature 10 to 32°C/ humidity 80% RH, temperature 18 to 27°C
Consumables,
Maintenance Unit
Toner cartridges, image drum
MB461/
MB461+LP/
ES4161 MFP
MB471 MB471w
MB491/
MB491+/
MB491+LP/
ES4191 MFP/
MPS4200mb/
MPS4700mb