Conforms to USDOL OSHA 29CFR 1910.1200 HAZCOM
8. Exposure controls/personal protection
Hand protection
Use a properly fitted, air-purifying or air-fed respirator complying with an approved
standard if a risk assessment indicates this is necessary. Respirator selection must be
based on known or anticipated exposure levels, the hazards of the product and the safe
working limits of the selected respirator.
Chemical-resistant, impervious gloves complying with an approved standard should be
worn at all times when handling chemical products if a risk assessment indicates this is
necessary. Considering the parameters specified by the glove manufacturer, check
during use that the gloves are still retaining their protective properties. It should be
noted that the time to breakthrough for any glove material may be different for different
glove manufacturers. In the case of mixtures, consisting of several substances, the
protection time of the gloves cannot be accurately estimated.
Safety eyewear complying with an approved standard should be used when a risk
assessment indicates this is necessary to avoid exposure to liquid splashes, mists,
gases or dusts. If contact is possible, the following protection should be worn, unless
the assessment indicates a higher degree of protection: safety glasses with side-
shields.
:
:
:
Body protection
Personal protective equipment for the body should be selected based on the task being
performed and the risks involved and should be approved by a specialist before
handling this product.
:
Skin protection
Other skin protection
:
Appropriate footwear and any additional skin protection measures should be selected
based on the task being performed and the risks involved and should be approved by a
specialist before handling this product.
9. Physical and chemical properties
Physical state
Melting point
Vapor pressure
Relative density
Vapor density
Solubility
Liquid.
Not available.
Not available.
Not available.
Not available.
Not available.
Citrus
Odor
pH
Brown.
Color
Evaporation rate
Not available.
Auto-ignition temperature
Flash point
Not available.
Closed cup: >93°C (>199.4°F)
Not available.
Not available.
Viscosity
Dynamic (room temperature): 70 mPa·s (70 cP)
Not available.
Odor threshold
Partition coefficient: n-
octanol/water
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
Appearance
Boiling point
:
Not available.
Flammability (solid, gas)
:
Not available.
Lower and upper explosive
(flammable) limits
:
Not available.
Decomposition temperature
:
Not available.
5/10
13/08/2014.
Date of issue
:
SDS #
FF890558_5
:
Code #