Installation Guide
 Page 11 
1.2-1.95in
(30-50mm)
1.2-1.95in
(30-50mm)
UNIT IS ADJUSTABLE
Keep in mind that the hooks on the mounting 
plate are smaller than the holes on the back of 
the unit. If you find that you don’t have ample 
room to connect embedded pipes to the indoor 
unit, the unit can be adjusted left or right by 
about 1.25-1.95in (30-50mm), depending on 
the model. 
Step 8: Mount indoor unit
If you installed new connective piping to the 
outdoor unit, do the following:
1. 
If you have already passed the refrigerant 
piping through the hole in the wall, proceed 
to Step 4.
2. 
Otherwise, double-check that the ends of the 
refrigerant pipes are sealed to prevent dirt or 
foreign materials from entering the pipes.
3. 
Slowly pass the wrapped bundle of refrigerant 
pipes, drain hose, and signal wire through the 
hole in the wall.
4. 
Hook the top of the indoor unit on the upper 
hook of the mounting plate.
5. 
Check that unit is hooked firmly on mounting 
by applying slight pressure to the left and 
right-hand sides of the unit. The unit should 
not jiggle or shift.
6. 
Using even pressure, push down on the 
bottom half of the unit. Keep pushing down 
until the unit snaps onto the hooks along the 
bottom of the mounting plate.
7. 
Again, check that the unit is firmly mounted 
by applying slight pressure to the left and the 
right-hand sides of the unit.
If refrigerant piping is already embedded in 
the wall, do the following:
1. 
Hook the top of the indoor unit on the upper 
hook of the mounting plate.
2. 
Use a bracket or wedge to prop up the unit, 
giving you enough room to connect the 
refrigerant piping, signal cable, and drain 
hose. 
3. 
Connect drain hose and refrigerant piping 
(refer to Refrigerant Piping Connection 
section of this manual for instructions).
4. 
Keep pipe connection point exposed to 
perform the leak test (refer to Electrical  
Checks and Leak Checks section of this 
manual).
5. 
After the leak test, wrap the connection point 
with insulation tape.
6. 
Remove the bracket or wedge that is propping 
up the unit.
7. 
Using even pressure, push down on the 
bottom half of the unit. Keep pushing down 
until the unit snaps onto the hooks along the 
bottom of the mounting plate.