Turn the Power Switch off and unplug the Drain Cleaner Cleaning Machine before performing any maintenance.
Always wear ANSI-approved safety glasses and heavy-duty work gloves when performing any maintenance.
1. Thoroughly flush Drain Cleaner cables with clean water after every use. Doing so will help prevent the build-up of sediment
and any drain cleaning chemicals still in the cable.
2. Once cables have been flushed, carefully tip the Drain Cleaner forward to empty out any remaining debris.
3. Once the cable is clean and dry, pull the cable from the drum.
4. Lubricate with oily rag as you feed cable back into drum.
WARNING! Do not attempt to remove a rotating cable.
Cleaning Drain Cleaner Cables
1. The Drain Cleaner should be cleaned as needed with hot, soapy water and/or disinfectants.
WARNING! Risk of shock! Do not allow water to get into the motor or any other electrical components.
2. Dry Drain Cleaner before storing or using again.
3. Once dry, thoroughly lubricate with a lightweight machine oil.
4. If Drain Cleaner drum is removed or changed, grease bearings with good general purpose grease.
Cleaning/Lubricating Housing
1. Loosen Belt Guard Knob and slide Belt Guard off from top of Drain Cleaner motor.
2. Use screwdriver to slide belt off back of Drain Cleaner drum.
3. Slide new belt into belt pulley above drum.
4. Slide new belt onto rear of drum until securely in place.
5. Slide Belt Guard pack into place above Drain Cleaner drum. Tighten Belt Guard Knob to lock Belt Guard back into place.
WARNING! Do not operate the Drain Cleaner without the Belt Guard in place.
Removing and Installing Belt
1. Remove old cable by pulling cable completely out. Separate cable from drum-connecting cable.
2. Connect new cable to drum-connecting cable and feed cable back into drum.