2 Reset System, Machine Initialization
2.1 System reset
All data which has been programmed, stored in the memory, etc. is deleted!!!! The status is displayed on the cash
register display by the character sequence "CL". Following this operation, the entire system is initialised, including
S Mode (refer to “Procedure for resetting the system”). The system reset is performed on changing the EPROM memory
during the initial installation, if necessary, or activated when the cash register does not respond to a warm start.
Procedure for resetting the system:
Turn the key to "OFF".
Switch the 220 V mains power supply off from the cash register, press and hold the
FEED key
and, while doing so, switch the 220 V power supply to the cash register back on.
The following appear in the display SYSTEM RESET
WARM START
CONTINUE
Release the
FEED key.
Turn the control key to PRG and then use the arrow buttons to select SYSTEM RESET in the display.
Press
CASH: The cash register executes a RESET and indicates Programming Mode in the display.
Cancelling the SYSTEM RESET: Use the arrow keys to move to CONTINUE and press
CASH.
If the cash register becomes blocked (due to a paper jam, maloperation, etc.), proceed as follows:
2.2 Warm start
This cash register start up should only be performed when the following key combinations prove unsuccessful:
Following key positions "REG", "X", "Z", "PRG".
1.
CLR 
2. FEED
3. NS #
A warm start can be performed manually as follows:
1. According to the procedure for a warm start.
2. By pressing the "RESET“ button on the cash register's main board (left of the EPROM).
Procedure for a warm start:
Turn the control key to "OFF".
Switch off the 220 V mains power supply from the cash register.
Press and hold the
FEED key and, while doing so, switch the 220 V power supply for the cash register
back on.
The following appears in the display: SYSTEM RESET
WARM START
CONTINUE
Release the
FEED key.
Leave the control key at "OFF" and use the arrow keys to select WARM START.
Press
CASH. The warm start procedure is completed.
Cancelling the WARM START: Use the arrow keys to move to CONTINUE and press the CASH key.