Page 1 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ ____________________________________________________________ PROGRAMMING INSTRUCTION ELECTRONIC CASH REGISTER OLYMPIA CM 1856F Version 3.01.
Page 2 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Table of contents: 1. 2. 3. 4. 5. 6. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. Page Basic Feature System RESET, initialisation machine Key description, Default key layout S – Mode, Service Mode Operation Machine establishment dump (Initialize basic system) 4.1 System building dump – Memory set, Training 4.2 Keyboard program mode 4.3 Print out establishment S - Mode 4.
Page 3 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 1. BASIC FEATURE Model Wat Weight Voltage Working temperature: : OLYMPIA CM 1856F : 25W : 8 kg : 220V : 0 – 400 C Department PLU TAX system Clerk Cashier Tender Media Track Item Track : 64 : 1.500 :8 : 26 – key :0 :5 : 200 : 70 Keyboard Number of key Customer display Clerk display : flat : 120 keys on basic Level and 71 keys on 1.Level,71 keys on 2.
Page 4 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Numeric Display: Receipt nr. Waiter name or nr. 0024 Mr Meier Fußzeile Display : 1. MO 1. 2. 3. 4. 5. 6. 7. 8. 2. 23.10 3. 8:35 MO Date Time Keypad level Preisebene Bon-Ein PC-Display IRC 4. T0 5. P1 6. BON 7. PC 8. IRC The first letter of the day T0= basis, T1= 1. level, T2= 2. level. P1= Price level 1 , P2= Price level 2.
Page 5 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Clerk system: Prior to the operation entry the Clerk logs in via a Clerk key (standard 26 keys). This system can be affected in the PRG mode (i.e. it can be entirely turned off). A change of Clerk (i.e. key) is not feasible before the completion of the appropriate operation.
Page 6 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 2. SYSTEM RESET. INITIALISATION MACHINE. System Reset: If the Cash Register is turned on (with the 220V mains), subsequent disconnecting/connecting an internal standby lithium battery shall cause initialisation of the Cash Register and its memories, and start of the Cash Register. (All programmed data, sales, etc. … are deleted !!!!).
Page 7 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Procedure for a warmstart: ¾ Turn key to position OFF ¾ Disconnect Cash Register from the 220 V mains Keep the key [ %21 pressed and simultaneously connect the Cash Register to the 220V mains ¾ Characters SYSTEM RESET WARM START CONTINUE shall appear on display ¾ Release the key [ ¾ leave the key in the OFF position and go with the arrow key to WARM START ¾ press the [ &$6+ ] key the reset i
Page 8 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 3. KEY DESCRIPTION. DEFAULT KEY LAYOUT. [ 5(&(,37 )((' ] : Receipt feed [ 3/8 ] : Direct PLU [ 0,186] : Minus (Discount) [ 3/86 ] : Plus (Add On) [ (& ] [ &255(&7,21 ] : Used as VOID key last transaction item only (PLU, DEP,…) [ 92,' ] : Used as VOID key otherwise (PLU, DEP,…) [ 5(7851 ] : Return item [ 68%727$/ ] : Subtotal during transaction [ ; / 7,0( ] : Qty during sales.
Page 9 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ [ 3$,' 287 ] [ ] : PO otherwise [ ] : Add on, Discount + % / -% (3 x 3) [ &/($5 ] : Clear entry [ &$6+ ] : Cash payment [ &+(&. ] [ &+$5*( ] [ &5(',7 ] : Payment key [ $.%.5. ] : Additional business receipt [ 1250$/ 35,17 ] : Tracking movement is not done [ 7$; 1 2 ] [ 7$.( 287 ] : TAX may be programming. Change of TAX. [ &$6+,(5] : Cashier entry – ID Code [ &/(5.
Page 10 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Default key layout (CM 1856F) – Basic Level: HOSPITALITY ▲ ▲ FEED Journal PLU 23 PLU 31 PLU 39 PLU 47 PLU 55 PLU 63 Group PLU 1 MAKRO 1 Keybord Level PLU 7 PLU 14 PLU 22 PLU 30 PLU 38 PLU 46 PLU 54 PLU 62 Group PLU 2 MAKRO 2 PLU 6 PLU 13 PLU 21 PLU 29 PLU 37 PLU 45 PLU 53 PLU 61 Group PLU 3 PLU 5 PLU 12 PLU 20 PLU 28 PLU 36 PLU 44 PLU 52 PLU 60 PLU 4 RA PO Ticket ON/OFF ▲ Print
Page 11 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Default key layout (CM 1856F) – 2. Level: REC.
Page 12 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Level 1 FEED JOURNAL PLU 123 PLU 131 PLU 139 PLU 147 PLU 155 PLU 163 PLU 171 PLU 107 PLU 114 PLU 122 PLU 130 PLU 138 PLU 146 PLU 154 PLU 162 PLU 170 PLU 106 PLU 113 PLU 121 PLU 129 PLU 137 PLU 145 PLU 153 PLU 161 PLU 169 PLU 105 PLU 112 PLU 120 PLU 128 PLU 136 PLU 144 PLU 152 PLU 160 PLU 168 Identical to basic keyboard level PLU 104 PLU 111 PLU 119 PLU 127 PLU 135 PLU 143 PLU 151 PLU 159 PLU 167
Page 13 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 4. S – MODE. SERVICE MODE OPERATION. Programming in S-mode (service) refers to the basic setting of Cash Register and to keyboard programming. When programming the basic setting of Cash Register (NN=01), a complete initialisation of Cash Register memory (i.e. its deletion and dynamic memory building) always occurs. 4.
Page 14 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Note: Surcharge / discount after the subtotal, i.e. of the whole sales slip, are calculated accurately, the total sum will be subsequently rounded according to the setting and surcharge / discount are calculated backward. When rounding the VAT, the VAT base is being rounded, i.e.
Page 15 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Example: S-mode: [ # / .9 ] [ &$6+ ] [ &$6+ ] [ &$6+ ] [ &$6+ ] [ &$6+ ] [ &$6+ ] [ &$6+ ] [ &$6+ ] Confirmation of memory allocation [ # / .
Page 16 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Example : For the PLU nr. 22, the value is 3 and the code is the PLU nr. 022 (3 figure) Entry: 3022 [FDVK] Entry: 1033 [FD6+] For the function key FREE the value is 10 and the code 33 see the table under 4.3 End of Programming [ # / .
Page 17 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Example: (Programming of function key no. 20 in the keyboard basic level) S-mode: [ # / .9 ] Press the [ Desired Key ] which is to be programmed. Enter the VALUE and the CODE and press [ # / .9 ] Example: (Programing of key PLU 20 in the keyboard basic level) S-mode: [ # / .9 ] Press the [ Desired Key ] which is to be programmed.
Page 18 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 4.4 Print out establishment S - Mode S-Mode: [ 12 6$/( ] Scrolling: Start printout: VALUE = 01 System building dump M/C#0000 CLERK#01 with the[ VALUE = 10 Machine establishment dump M/C#0000 CLERK#01 CASHIER#01 90 DECIMAL POINT: ROUNDING: ROUNDING TAX: DATE FORMAT: AUTO CUTTER: MODE - NORMAL 2 1 2 0 0 12:00 01-05-2006 12:00 VALUE = 21 Key assign – 1.
Page 19 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 5. PRG – MODE. PROGRAM MODE OPERATION. Programming in the PRG-mode refers to programming of Cash Register features; for programming basic data (DEP, Account Items, TAT,...), features of X, Z – Reports and others as per individual sections, see below. General programming procedure: Key turned to PRG mode: The cash desk display shows all programme sections.
Page 20 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 5.1Program Department (SECTION 01) PRG-Mode: [ 12 6$/( ] 1. Scroll: using the cursor keys line (on the display screen up-down) 2. Scroll: using the cursor keys page (by entry e.g.WG1,WG2,WG3, etc.) Entry programme value: [ &$6+] VALUE or TEXT [12 6$/(] End programming of the respective section Structure Department: Field Record Num. VALUE max. 18 character ASCII max.
Page 21 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Example: (to program DEP4, name:STEAK, price:23.50, TAX:1, status:00) PRG-Mode: 2X [ 12 6$/( ] Key page down 67($. [ &$6+ ] [ &$6+ ] [ &$6+ ] [ &$6+ ] [ &$6+ ] [ &$6+ ] [ &$6+ ] [ &$6+ ] Start programming Section Jump to entry WG # 3 store caption for DEP store Price1 skip Price2 store TAX#1 skip field „Department group#“ skip field „HALO/LALO“ skip field „Not use“ store Status ….
Page 22 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 5.3 Program PLU (SECTION 03) PRG-Mode: [ 12 6$/( ] [ &$6+ ] choice / new PLU (NUMBER PLU/EAN#) 1. scroll using the the cursor keys line-up, line-down 2. scroll using the cursor keys page (possibility) [ 92,' ] entry prg. value VALUE (on the display screen up down) (by entry e.g. PLU1,PLU2,PLU3, etc.) (delete current PLU and proceeded to next PLU) [ &$6+ ] [ # / .
Page 23 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ GG = number of group PLU (0 – 99) I = status PLU (0 – 11) HL = H L H 0 1 2 3 4 5 6 7 0 1 2 3 4 5 10 11 : : : : : : : : standard PLU, fixed price negative PLU, fixed price galon PLU, open price galon PLU, negative, open price standard PLU, open price negative PLU, open price scale, standard PLU, fixed price scale, negative PLU, fixed price = High Amount Lock Out (0 – 7) = Low Amount Lock Out
Page 24 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 5.4 Program Link PLU (SECTION 04) PRG-Mode: [ 12 6$/( ] choice / new PLU (NUMBER PLU/EAN#) 1. Scroll: using the the cursor keys line-up, line-down (on the display screen up down) 2. Scroll: using the cursor keys page (by entry e.g. PLU1,PLU2,PLU3, etc.) (possibility) [ 92,' ] (deleted Link PLU and proceeded to next linkPLU item) entry prg.
Page 25 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Structure PLU group name PLU: Field Record Num. VALUE 1: Group name 01-99 : GR-PLU# max. 18 character ASCII PLU group keys can be set as permanent keys in the keyboard programming. 5.6 Program Clerk (SECTION 06) PRG-Mode: [ 12 6$/( ] 1. Scroll: using the cursor keys line-up, line-down (on the display screen up down) 2. Scroll: using the curor keys page entry prg. value (by entry e.g.
Page 26 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ S1S2 S3S4 = = status (Clerk Rights) CODE “S1” Prohibit „RETURN“ Prohibit „VOID“, „EC“ Prohibit „NO SALE“ 0 CODE “S2” Prohibit X – Reports (Training) Prohibit Z - Reports Prohibit PO entry 0 1 [ 2 3 [ [ [ 4 5 [ [ 1 [ 2 3 4 7 [ [ [ [ [ [ 5 [ [ [ [ 6 [ [ 4 5 [ [ [ 6 7 [ [ [ [ [ status (Clerk Rights) CODE “S3” Prohibit Z – Reports accum.
Page 27 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Program Waiter Rights (SECTION 17) This section range can be used to modify waiter rights.
Page 28 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 5.7 Program Cashier (SECTION 07) PRG-Mode: [ 12 6$/( ] 1. Scroll: using the cursor keys line-up/down (on the display screen up down) 2. Scroll: using the cursor keys page (by entry e.g. waiter 1, waiter 2, etc.) entry prg. value [ &$6+ ] VALUE [ 12 6$/( ] end programming Section Structure Cashier: Field Record Num.
Page 29 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ H 0 1 2 3 4 5 6 7 S1S2 = Digits No limit 1 2 3 4 5 6 7 Digits of item entry permit maximum 9 99 999 9999 99999 999999 9999999 L 0 1 2 3 4 5 6 7 Digits No limit 1 2 3 4 5 6 7 Digits of item entry permit minimum 1 10 100 1000 10000 100000 1000000 status (prohibit / compulsory operation) CODE “S1” Over tender inhibitted Under tender inhibitted Not open drawer 0 CODE “S2” Not use SUBTOTAL compulso
Page 30 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 5.10 Program Key %+, % - (SECTION 10) PRG-Mode: [ 12 6$/( ] entry prg. value [ &$6+ ] VALUE [ 12 6$/( ] end programming Section Structure: Field 1: Add on % 2: Discount % 3: Add on %1 4: Discount %1 5: Add on %2 6: Discount %2 Record Num. 01-06 : % # 5.11 VALUE 0.00 - 99.99 % 0.00 - 99.99 % 0.00 - 99.99 % 0.00 - 99.99 % 0.00 - 99.99 % 0.00 - 99.
Page 31 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 5.13 Program P-Register (Machine option) (SECTION 13) PRG-Mode: choice register [ 12 6$/( ] (P- REGISTR#) entry prg.
Page 32 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ REGISTER P-02: CODE “M3” Print #Machine Number on receipt Print receipt number on receipt Print “SUBTOTAL” amount after use this key 0 1 2 3 4 5 6 7 [ [ [ [ [ [ [ [ [ [ [ [ CODE “M4” Print item counter on receipt Print logo message on receipt Print clerk name on receipt 0 1 2 3 4 5 6 7 [ [ [ [ [ [ [ [ [ [ [ [ REGISTER P-03: CODE “M5” Reset counter on Z-Report day issuing Reset cou
Page 33 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ REGISTER P-07: CODE “M13” Print tax amount after tender amount on receipt Pirnt total tax amount on receipt only Not print tax rate on receipt 0 1 2 3 4 5 6 7 [ [ [ [ [ [ [ [ [ [ [ [ CODE “M14” Print Logo/Ad message on journ. (549,579R,579 only) Print details at PRG,SMode Print gradoval logo on receipt (359T+, 396F+/649F+ only) 0 1 2 3 4 5 6 7 CODE “M16” Endless elec.
Page 34 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ REGISTER P-12: CODE “M23” Cutting disable on kitchen printers Not print OLYMPIA ® Kassensysteme Active Kitchen orders at direct sale 0 1 2 3 4 5 6 7 [ [ [ [ [ [ [ [ [ [ [ [ CODE “M24” print zero prei-plu only at tichet not at Invoice Compulsary cash declaration active (Fin.R.
Page 35 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 5.15 Program Time (SECTION 15) PRG-Mode: [ 12 6$/( ] entry prg. value [ &$6+ ] VALUE [ 12 6$/( ] end programming Section Structure: Field Record Num. HHMM: HH = 00 – 23 MM = 00 – 59 1: Time 01: TIME 5.16 VALUE Program Currency – FC (SECTION 16) PRG-Mode: choice FC [ 12 6$/( ] [ 12 6$/( ] (FC#) 1. Scroll using the cursor keys line-up, line-down (by currency entries) 2.
Page 36 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Structure: Note: 5.18 Record Num. Field 01-26 : KEY# 1: #Clerk Number VALUE 01 – 99 As a factory setting, the key #16 is the training key.
Page 37 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ REGISTER P-03: CODE “M5” Number of free line before GCP printer (42) 5.
Page 38 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ REGISTER P-03: VALUE “M5” Print DATE, TIME bold 0 1 2 3 4 5 6 7 [ [ [ Print LOGO message bold [ [ Orderbon # [ [ No print the line „ Netto TL And VAT TL on receipt [ [ [ Print AD message bold [ VALUE “M6” Print cooking message bold [ 0 1 2 3 4 5 6 7 [ [ [ [ [ [ [ [ [ [ [ [ 5.
Page 39 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 5.22 Program COM port machine (SECTION 23) PRG-Mode: choice COM port [ 12 6$/( ] [ 12 6$/( ] (COM port#) 1. single-step operation using the cursor keys line-up, line-down (by records ports) 2. single-step operation using the cursor keys page (by items of one port) entry prg. value VALUE [ &$6+ ] [ 12 6$/( ] end programming Section Structure port: Field Record Num.
Page 40 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Default settings COM Port# 01 02 03 04 05 Label COM B COM A COM D COM C Setting (AB) 05:DTR/DSR, BCR 00:DTR/DSR, Not use 01:DTR/DSR, PC 03:DTR/DSR, SLIP prn. 04:DTR/DSR, Kitchen prn. Setting 2 (CD) 10:9600bps, 7bit 31:38400bps, 8bit 31:38400bps, 8bit 11:9600bps, 8bit 11:9600bps, 8bit Setting 3 (EF) 11:Odd,2 stop Bit 10:Odd,1 stop Bit 10:Odd,1stop Bit 00:Bez, 1stop Bit 00:Bez, 1stop Bit 5.
Page 41 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 5.26 Program AD message (SECTION 32) PRG-Mode: 1. Scroll: [ 12 6$/( ] using the cursor keys line-up, line-down entry prg. value [ &$6+ ] VALUE [ 12 6$/( ] end programming Section Structure: Field Record Num. 01 - 5: LINE# 6 Line# VALUE 1: Caption Text „INVOICE“ max.
Page 42 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 5.28 Program Cooking message (SECTION 40) PRG-Mode: [ 12 6$/( ] choice cooking (MESSAGE#) 1.scroll: using the cursor keys line-up, line-down (by the entries of the message entrys) 2.scroll: using the cursor keys page (by the position of a message) entry prg. value [ &$6+ ] VALUE [ 12 6$/( ] end programming Section Structure massage: Field Record Num.
Page 43 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 5.30 Program Logo message for SLIP printer (GCP) (SECTION 42) PRG-Mode: Scroll: [ 12 6$/( ] using the cursor keys line-up, line-down entry prg. value [ &$6+ ] VALUE [ 12 6$/( ] end programming Section Structure: Field Record Num. VALUE 1: Captione 01 – 4: LINE# max. 48 character ASCII 5.31 Program Kitchen files – Kitchen printers (SECTION 43) PRG-Mode: [ 12 6$/( ] choice kit.
Page 44 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 5.32 IRC configuration (option) (SECTION 50) [ 12 6$/( ] PRG-Mode: 1. The display shows a combination list with 16 X items 2. Confirm with [ &$6+ 3. ] key End programming with [12 6$/(] key 4. The group list is automatically requested and the group number is entered in the list Now the Cash Register prints out an IRC configuration, i.e.
Page 45 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 5.34 STOCK – PLU, LINK PLU STOCK COUNTER ADJUSTMENT Addition of inventory stock: X-Modus: X-Mode: All reports are shown in the display, enter 97, press the [ .9 ] key and use the cursor keys image/page up – down to go to the item stock indicator. Confirm with the [ &$6+ ] key, PLU-stock is shown, confirm with the [&$6+] key 1.
Page 46 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Program Report Link Macro (SECTION 31) S-mode [# / 16 ] Display CM 1856F 31 Key Links 1,2 X/Z CM 1840-1846S-F Macro key 1 "X" mode [XXXXXXXXXXXXXXXX] 31 [#/16] Macro key 2 "X" mode XXXXXXXXXXXXXXXX 32 [#/16] Macro key 1 "Z" mode XXXXXXXXXXXXXXXX 33 [#/16] XXXXXXXXXXXXXXXX Macro key 2 "Z" mode 34 [#/16] Up to 16 key sequences can be programmed per macro key in "X" or "Z" mode.
Page 47 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Programming code: 0–9 Enter numbers Enter the two-digit report number. *a Line up *b Line down *c Cash "X" mode once: display report; twice: print report "Z" mode once: print report *d Cut paper Paper is cut after printing report Continue with the next report number *e No sale *f End of macro link Example: You want to program linked reports.
Page 48 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 6. Tracking print contents by „Ticket type“,“Order groups“, „Kitchen printer“ Hospitality-Version only The order system can be activated in the programming section of the ECR using the PRG – control key setting. Programming section (01) Department group = Ticket type 6 or 7 1.System (Ticket type) Type 6 – Ticket/consolidated. The ticket is printed upon closing of table. Type 7 – Ticket/normal.
Page 49 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 2.System (Order groups) The order-system can be activated in the programming-section of the ECR using the PRG – control key setting. Programming-section (01) Department groups = ticket type 4 Programming-section (03) PLU = (column 14) Order-groups 10-9 If the Order group 00 is set it will not be printed. This order-system enables printing with internal printer according to the set parameters possible.
Page 50 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 3.System (Kitchen printer) The ordering-system can be activated in the programming-section of the ECR using the PRG – control key setting. The system will allow up to eight different KP# tickets. The following ticket types are possible on an external kitchen printer.
Page 51 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ # 06 = single ticket without consolidated ticket, similar items using only single ticket. TRACK# 001 1 KP#6 PLU 101 01-05-2006 2-10 000434 CLERK 01 ---------------------CUT-------------------------TRACK# 001 2 KP#6 PLU 102 01-05-2006 2-10 000435 CLERK 01 # 07 = single ticket + consolidated ticket, similar items using single ticket.
Page 52 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ # 08 = single ticket without consolidated ticket, similar items using single ticket TRACK# 001 1 KP#8 PLU 101 01-05-2006 2-10 000434 CLERK 01 ---------------------CUT-------------------------TRACK# 001 1 KP#8 PLU 102 01-05-2006 2-10 000435 CLERK 01 ---------------------CUT-------------------------TRACK# 001 1 KP#8 PLU 102 01-05-2006 2-10 000436 CLERK01 The Text for the KP# can be programmed i
Page 53 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Table of Reports: REPORT - DETAIL KEY SEQUENCE MODE Financial Report Day X/Z 01 [CASH] Financial Report Accumulative X/Z 02 [CASH] Department Group Report Day X/Z 15 [CASH] (On case Z-Mode Report „03“deleted in time) Department Group Report Accumulative X/Z 16 [CASH] (On case Z-Mode Report „04“deleted in time) Group PLU Report Day X/Z 17 [CASH] (On case Z-Mode Report „05“deleted in
Page 54 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ PLU Clerk sale Report Day X/Z 07 [CASH] Clerk Report Day X/Z 08 [CASH] (starting clerk#) [#/NO SALE] (ending clerk#) [#/NO SALE] 08 [CASH] Clerk range Report Day Clerk Report Accumulative X X/Z Clerk range Report Accumulative Cashier Report Day Cashier Report Accumulative Cashier range Report Accumulative Hourly Report (starting clerk #) [#/NO SALE] (ending clerk #) [#/NO SALE] 09 [CASH] X X
Page 55 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ NOTE The electronic journal can only be deleted on the cash desk if the ‚electronic journal’ item of the machine options is not active. 9. CHARACTER TABLE. ALPHABET KEY LAYOUT FOR CAPTION.
Page 56 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Keys – indicate individual characters A, B, C, D, ...... Key “ws” = bold character, e.g. bold character “A” is entered by pressing the keys: ...... :6 $ Key „SPACE“ = space Keys *A,*B,*C,*D,*E indicate keys for entry of character codes in HEX. system, e.g. “m” = *A *B *C *D *E *F Q W E R T Z U I O A S D F G H J K L Y X C V B N M space space space space , .
Page 57 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 10.
Page 58 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Receipt paper end Error: Alpha display INTERNAL PRINTER PAPER FEED OUT E 22 INTERNAL PRINTER HEAD OPEN E 23 Receipt Head up Error: Alpha display Code compulsory Error (Tender): Alpha display CODE REQ E 32 St compulsory Error (Tender): Alpha display SUB–TL REQ E 33 AMOUNT REQ E 34 DRW E 35 At compulsory Error: Alpha display Drawer open Error: Alpha display OPEN FC# request Error: Alp
Page 59 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Track full (Bill buffer full, item sale) Error: Alpha display TRACK FULL ITEM SAVE E 42 Track full (Bill buffer full, item not sell) Error: Alpha display TRACK FULL E 43 Cooking message compulsory Error: Alpha display COOK REQ E 44 Clerk ID Error: Alpha display CLERK ID ERROR E 45 Ticket Type Error: Alpha display REC TYPE E 46 Electric Journal full Error: Alpha display ELE–J WARN E
Page 60 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ GCP status Error: Alpha display GCP STATUS GCP communication Error: Alpha display GCP ERROR
Page 61 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 11.
Page 62 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 12. INSTRUCTIONS FOR OLYMPIA-MANAGER / OLYMPIA-HELPER Installation The Data-CD contains a folder named OLYMPIA Manager / OLYMPIA Helper. Open this folder and doppel click on < Setup Manager > to install the computer program. Follow the instructions on the screen. The OLYMPIA Manager automatically copies an icon to the Desktop.
Page 63 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 13. SERVICE-PROGRAMM im „S“ MODE START Program with: 1. Plug out the Mains plug 2. Set the key position on the cash register to “S“ 3. Plug in the Mains plug 4. Scroll with the Keys [3DJH 8S] and [5(&(,37 21 2))] Back with [=:] Key. Screen display in service mode: 1. LOAD FLASH MEMORY : 2. FACTORY TEST : 3.
Page 64 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 14. FLASH-PROGRAM You can use this to transfer new firmware to the cash register, exchanging an e-prom is therefore no longer necessary. This programme can only be run by a OLYMPIA-specialized dealer in the OLYMPIA Manager. 1. Pull the mains cable 2. Set the key position on the cash register to “S” 3. Plug in the mains cable. 4.
Page 65 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 15. Modem for telecommunication with the cash register Use an analogue standard modem (e.g. ACER 56 surf) Installation: - Connect the modem to a Com port on your computer. - On your desktop (PC), click on the icon “Olympia Manager“ or “Olympia Helper“ - Select “Properties” with the left mouse button.
Page 66 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 16. CONNECTION: SCANNER Tested Scanners are from the companies METROLOGIC, models ORBIT und VOYAGER Adjust the scanner by scanning the data sheet. 1. If the scanner is connected to the cash register, the Sanyo ID Code is also scanned in. 2.If the scanner is connected to the PC, then the Sanyo ID Code is left out. Add an ARTICLE: Programme an article on the PC using the scanner 1.
Page 67 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 17. CONNECTION GCP- receipt printer In the cash register programme section 23, the GCP printer model Epson TMU 295 is preset. Connect the GCP printer to the cash register port Com 4 = port D.
Page 68 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ 18. Connecting the SPRINTER module to the cash register Olympia CM 1856F || The printers must have the following basic settings: ( serial Interface) Baut rate Data Lenght Parity Flow control Low Power Mode 9600 BPS 8 bit Non X on/X off ON KP-MODULE for the kitchen printer Connect the printer cable from the KP-MODULE to the kitchen printer 1.
Page 69 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ Activate SPRINTER wireless module Connection to the power supply Before you connect the SPRINTER system to the power supply, the cash register and the printer should both be turned on. Plug the adapter into the powersocket. Then connect the adapter with the power supply connection on the module. A self-test starts automatically. The green LED and the red LED blink once.
Page 70 OLYMPIA CM 1856F _______________________Programming Instruction___________________________________ ____________________________________________________________ Olympia Business Systems Vertriebs GmbH reservers alterations with regard to content and technical details. All given data are nominal values only. The described features and opinions can vary depending on country-specific requirements.