Operation Manual

Door/Window Contact
G
9
Only assemble the door/window contact in the position and alignment illus
trated in Fig. 4. Otherwise, there is no guarantee that the door/window con
tact will function properly.
1. Open the door/window detector by pressing the lock downwards in direction of
the arrow and sliding the upper section towards the lock. Refer to Fig. 5.
2. The assembly shell of the door/window detector is fixed in place on the door/
window by means of double-sided adhesive tape or two screws. Refer to Fig. 7.
When using double-sided adhesive tape, pay attention that the application
surfaces are free of dust and grease.
3. Insert the AAA batteries in the battery compartment (pay attention to correct
polarity). Refer to Fig. 6.
4. Slide the upper section of the door/window detector onto the assembly shell
until it snaps in place.
5. The magnet unit is comprised of a fixation base, two spacers, a permanent
magnet and a cap. Dismantle the unit into its individual parts by pulling it apart.
Refer to Fig. 8.
6. The fixation base is secured in place by means of double-sided adhesive tape
or two screws. Pay attention to the maximum distance of 5 mm to the door/window
detector. Refer to Fig. 1.
When using double-sided adhesive tape, pay attention that the application
surfaces are free of dust and grease.
7. Screw the permanent magnet firmly to the fixation base. Check the height in
relation to the door/window detector beforehand and use the optionally available
spacers which can be plugged onto the fixation base. Refer to Fig. 8.
8. Place the cap on the permanent magnet.
Registering the Door/Window Contact on the
Alarm System
The door/window contact must be registered on an alarm system from the Protect
series. This can also be used to activate further alarm systems and send alarm
signals via the telephone network.
1. Select the
Register menu option on the alarm system.
2. Trigger the sensor by opening the window, for example.
3. When the message Magn. Sens. followed by a number appears in the alarm
system display, registration on the alarm system was successful.
4. Change the entry in the alarm system as necessary.
To configure the alarm system, please refer to the manual related to the
alarm system.
Technical Data
Weight: 38 g
Dimensions (W x H x D): Door/Window detector
15.7 x 106.8 x 22 mm
Magnet unit
11.5 x 48 x 34.5 mm
Frequency: 868 MHz
Batteries 2 x AAA batteries