OPERATION, MAINTENANCE AND SAFETY INSTRUCTIONS Model - Brigadier/Lancer Gas Radiant Convection Room Heater
IMPORTANT SAFETY INSTRUCTIONS The OMEGA ALTISE gas space heaters are a manually operated, portable, flueless radiant convection heater for use with Natural gas or Universal LPG. The heater is supplied with an approved flexible hose. Note: A label is attached to the rear of the heater stating the type of gas for which it has been manufactured and adjusted.
GENERAL HEATER PARTS GAS SUPPLY DATA Refer to the rating label attached to the rear of each appliance, the gas supply data as well as the gas type for which the heater has been tested and adjusted for is shown.
OPERATING INSTRUCTIONS GAS SUPPLY Your heater is fitted with a flexible hose and bayonet coupling which enables you to connect or disconnect it from the gas supply. TO CONNECT Insert the coupling end into the wall bayonet fitting firmly and rotate the knurled section clockwise to it’s locked position. TO DISCONNECT Apply firm forward pressure to the knurled area, rotate anti clockwise and pull towards you. The hose should now come away from the wall bayonet fitting.
GAS CONNECTION The bayonet plug on the factory fitted flexible hose simply plugs into your home bayonet fitting by pushing and rotating 1/4 turn clockwise. To disconnect, rotate the bayonet plug counter clockwise and gently remove from the wall fitting. CASTORS Lay the unit gently on its back and push the castor's into place in the slots. The castor's will click when they are located. NOTE: Not all units are supplied with castors.
OPERATING INSTRUCTIONS LIGHTING INSTRUCTIONS Open the control box lid, depress and hold down the ‘ON/IGNITION/LOW’ button. This button operates the sparker, which in turn ignites the pilot flame and the low setting burner. It is necessary to hold down the ‘ON/IGNITION/LOW’ button firmly for at least 20 seconds to allow the gas valve to ‘lock in’. If the burner fails to light, repeat the ignition sequence described above.
WARNINGS DO NOT OPERATE THIS APPLIANCE BEFORE READING THE INSTRUCTION BOOKLET DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE DO NOT STORE CHEMICALS OR FLAMMABLE MATERIALS OR SPRAY AEROSOLS NEAR THIS APPLIANCE DO NOT OPERATE WITH PANELS, COVERS OR GUARDS REMOVED FROM THIS APPLIANCE DO NOT OPERATE IN A BATHROOM OR BEDROOM DO NOT OPERATE IN AN UNVENTILATED ROOM DO NOT OPERATE IN A ROOM WITH A VOLUME LESS THAN THAT SHOWN IN THE TABLE BELOW DO NOT CONNECT TO AN U.L.
CLEANING IMPORTANT: Disconnect gas and electrical supplies before cleaning any internal surfaces. Malfunctions caused by excessive lint or dust build up will not be covered under warranty. Warning: Regular cleaning will not remove the requirement for regular servicing by authorised personnel. The outer surfaces of the heater should only be cleaned or dusted with a damp cloth. Access to the area in front of the tiles is achieved by opening the dress guard as follows.
FAULT FINDING SYMPTOM POSSIBLE CAUSE Spark failure (1) Faulty igniter (2) Incorrect spark gap (3) Loose or faulty connections REMEDY Replace Reset to 4.
IM Rev: 1.