User Manual
Seasonal Cleaning
If the machine is not be unused for a long time, please follow these steps :
• Pull out drainage plug upper / lower to empty any water out.
• Let the machine run under fan mode for 2 hours to dry out the machine internals
• Turn off the appliance, switch off the power point and remove the plug.
• Clean and dry filters , then reinstall them .
• Pull out exhaust pipe for safekeeping .
• Put the machine into a plastic bag , and place it on a dry place.
Troubleshooting
Please contact professional serviceman without delay in following situation
Trouble Cause Solution
Power off Power on
“P2” flashes on screen or
water-full indicator turns on
Drain water out
Machine
cannot work
Timer-off turns on
Turn off machine for three minutes,
then restart it.
Direct sunlight Draw the curtains
Door and windows are open ,
many heat sources in the
room .
Close the door and windows, move
out heat sources.
Filters are too dirty. Clean or replace filters
Machine auto-
restarts
frequently
Air-inlet or air out-let is
blocked
Remove blockage
Too noisy Machine is not on flat ground.
Place it on flat and solid ground,
avoiding shaking
Compressor
cannot work
Compressor time-delay
protection turns on
Wait for 3 minutes, then restart the
machine after temperature reduces .
Note: If the machine is not working please contact your authorised agent.