OPERATION, MAINTENANCE AND SAFETY INSTRUCTIONS FOR OMEGA ALTISE AIR CONDITIONER Model : OAPC36RW OMEGA ALTISE
Contents IMPORTANT SAFETY INSTRUCTIONS........................................................................................................... 3 TECHNICAL DETAILS ...................................................................................................................................... 8 FEATURES ....................................................................................................................................................... 9 PRODUCT OVERVIEW ............................
IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: Read the safety precautions of this booklet carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage.
IMPORTANT SAFETY INSTRUCTIONS WARNING: flammable materials Service indicator, read technical manual Operator’s manual; operating instructions • This unit is not intended for use by children (including children) with reduced physical, sensory or metal capabilities, or lack of experience and knowledge, unless they been given supervision or instruction. Children being supervised not to play with the appliance.
IMPORTANT SAFETY INSTRUCTIONS Repair to sealed components • During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
IMPORTANT SAFETY INSTRUCTIONS Removal and evacuation • When breaking into the refrigerant circuit to make repairs – or for any other purpose – conventional procedures shall be used. However, for flammable refrigerants it is important that best practice is followed since flammability is a consideration. The following procedure shall be adhered to: • Remove refrigerant. • Purge the circuit with inert gas (optional for a2l). • Evacuate (optional for a2l). • Purge with inert gas (optional for a2l).
IMPORTANT SAFETY INSTRUCTIONS (c) Before attempting the procedure, ensure that: • Mechanical handling equipment is available, if required, for handling refrigerant cylinders. • All personal protective equipment is available and being used correctly. • The recovery process is supervised at all times by a competent person. • Recovery equipment and cylinders conform to the appropriate standards. (d) Pump down refrigerant system, if possible.
IMPORTANT SAFETY INSTRUCTIONS Warnings for Disposal Refrigerant used for the air-conditioner are flammable. Therefore when the air-conditioner is scraped, it shall be kept away from any fire source and be recovered by a special recovering company with corresponding qualification other than be disposed by combustion, so as to prevent damage to the environment or any other harm. Correct Disposal of this product This marking indicates that this product should not be disposed with other household wastes.
FEATURES • • • • • • • • • • • High Capacity in a compact size with cooling, heating, dehumidifying and ventilating function Temperature setting and display LED Digital display Electronic control with built-in timer, sleep mode Self-evaporating system for better efficient Auto shut off when tank full Automatic restart in the event of power outage Auto defrosting function at low ambient temperatures Remote control 3- speed fan Casters for easy mobility PRODUCT OVERVIEW 1. 2. 3. 4. 5. 6. 7.
INSTALLATION INSTRUCTIONS Unpacking • • Unpack the carton and take the appliance and accessories out. Check the device after unpacking for any damage or scratches on it. Accessories: 1. 2. 3. 4. Exhaust hose Hose connector Window kit adapter Remote control 5.
INSTALLATION INSTRUCTIONS Choose your location • • • • If tipped more than 45°, allow the unit to set upright for at least 24 hours before starting up. Place the unit on a firm, level surface in an area with at least 50cm of free space around it to allow for proper air circulation. Do not operate in close proximity to walls, curtains, or other objects that may block air inlet and outlet. Keep the air inlet and outlet free of obstacles. Never install the unit where it could be subject to: I.
INSTALLATION INSTRUCTIONS Step 2: Connect the windows kit adapter to the other end of the exhaust hose. Step 3: Extend the adjustable window kit the length of your window. Connect the exhaust hose to the window kit. Step 4: Close your window to secure the kit in place. It needs to hold the windows kit firmly in place, secure the window kit with duct tape if required. It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency.
INSTALLATION INSTRUCTIONS Step 5: Attach the hose connector to the exhaust air outlet of unit. Step 6: Adjusting the length of the flexible exhaust hose and avoid bends in the hose. Then place AC near an electrical outlet. Step 7: Adjust the louver at the air outlet, and then switch on the unit.
OPERATING INSTRUCTIONS CONTROL PANEL AND DISPLAY 1. POWER (LED) 2. MODE 3. INDICATORS 4. ADD 5. SWING 6. TIMER 7. FAN 8. INDICATORS LED for fan speed (Low, middle and high) 9. DIGITAL DISPLAY Displays timer setting and room temperature 10. MINUS Decreasing the desired temperature or timer setting 11.
OPERATING INSTRUCTIONS REMOTE CONTROL START-UP AND SHUTDOWN • • • • Press POWER button to turn the unit on. The unit runs in a FAN mode as default. Press MODE button to select the desired operation mode. Press POWER button again to turn off the power. OPERATION MODE The unit has five operation modes: Cool, heat, fan, dry and sleep (Sleep mode is only optional on the remote control) COOLING MODE • • • • • Select the cool mode to lower the temperature in your room.
OPERATING INSTRUCTIONS HEATING MODE • • Press MODE button repeatedly until the LED of HEAT operation lights up. Press ADD/MINUS button to set the temperature higher than the room temperature. The fan speed can also be set by pressing SPEED button. Note: The drainage hose should be attached to the unit for continuous operating. VENTILATION MODE • • • Press MODE button repeatedly until the LED of FAN operation lights up. In ventilation mode the room air is circulated, but not cooled.
OPERATING INSTRUCTIONS AUTOMATIC DEFROST At low room temperatures, frost may build-up at the evaporator during operation. The unit will automatically start defrosting and the POWER LED blinking.
CLEANING WARNING: ALWAYS UNPLUG THE CORD BEFORE MOVING OR SERVICING, DO NOT IMMERSE APPLIANCE IN WATER! • Cleaning and maintenance shall not be made by children without supervision. • Cleaning of this appliance should be done every two weeks. • Always make sure that the appliance is completely dry before connecting back to the mains supply. • Make sure no water enters the control panel or fan motor. • Store the appliance in a cool dry place. Dust collects on the filter and restricts the airflow.
CLEANING CLEANING UP OF REFRIGERANT 1. Gas/vapor heavier than air. May accumulate in confined spaces, particularly at or below ground level. 2. Eliminate every possible source of ignition. 3. Use appropriate personal protection equipment (PPE). 4. Evacuate unnecessary personnel, isolate, and ventilate area. 5. Do not get in eyes, on skin, or on clothing. Do not breathe vapours or gas. 6. Prevent entry to sewers and public waters. 7. Stop the source of the release, if safe to do so.
SERVICING Please follow these warnings when to undertake the following when servicing an appliance with R290. Checks to the area Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
SERVICING • Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded. Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures.
TROUBLESHOOTING Do not repair or disassemble the unit by yourself, unauthorized repair attempts will invalidate the warranty and may cause bodily harm. Symptom Inspection Solution Check the power connection in securely. Insert the power cord securely into the wall outlet. Check if the water level indicator lights up? Empty the drain pan by remove the rubber plug. Check the room temperature. The range of operating temperature is 5-35℃. Check the air filter for dirt.
WARRANTY AUSTRALIAN CUSTOMERS Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
A division of Shriro Australia Pty Ltd 2-34 Davidson Street Chullora NSW 2190 In Australia: 1300 795 572 In New Zealand: (09) 415 6000 www.omegaaltise.