OPERATION, MAINTENANCE AND SAFETY INSTRUCTIONS OMEGA ALTISE PANEL HEATERS OAPE2000B & OAPE2000W I HEAT LIVE RELAX
IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: Read the safety precautions of this booklet carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage.
CONTROL FUNCTIONS 1. Power On/Off Button 2. Mode Button - Temperature/ Timer setting 3. Up Button 4. Down Button 5. Temperature/ Timer Display 6. Power Indicator 7. Heater Operation Indicator (Red) 8. Delay Off Timer Set Indicator (Green) 9. Constant Frost Protection Indicator 10. Lock Indicator 11. Degrees Celsius Indicator 12. Time Indicator 13. Tilt Warning Indicator 14. Vent, Warm Air Discharge 15. 240 Volt Power Cord and Plug 16. Air Inlets 17. Castors and Wheels A. Control Panel Console B.
OPERATING INSTRUCTIONS TURNING ON & OFF Press the power button on the the control console once to start. The LED display will now show the last temperature setting. If this temperature is above the room temperature the red operation indicator will illuminate. To switch the heater off, press the power button. The shutdown of the heater will be accompanied with a chime sound, to confirm the heater is now off. SETTING TEMPERATURES To change the temperature setting press the mode button once.
OPERATING INSTRUCTIONS ANTI FROST PROTECTION If the temperature is set to 5C°, then the constant frost protection program will be activated and the constant frost protection indicator will be illuminated. LOCK FUNCTION The lock function is designed to prevent accidental operation of the heater. To activate the lock press and hold the up and down button until the padlock symbol is displayed. To de-activate the lock, press and hold the up and down button until the padlock symbol disappears.
INSTALLATION GUIDE This heater can either be mounted to a wall or used with the supplied castors and wheels. Please note the following safety warnings: This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Always use the control panel or castor supports when moving the heater (when not wall mounted). Keep combustible materials such as furniture, pillows, bedding, papers, clothes and curtains at least 1 meter from the front & top of the heater and keep them at least 0.
Attach the supplied right angle mounting brackets to the underside of the heater (front hole of bracket) using the rear most of the pre installed case screws as shows in the diagram. Check for strength. Carefully place the heater (slightly tilted forward) onto the hooks at the bottom of the bracket & rotate back so the clips fix back into their original holes. Check that they are fixed correctly. If possible, have a second person help to check for alignment as the heater is attached.
HINTS & TIPS Where possible, your electric panel convection heater should be connected to a power outlet that uses a separate 10 amp power circuit than other items. This will avoid overloading your household fuse. In the event that your household fuse is overloaded and trips, please note this is normally caused by the use of excessive power outlets at the same time your heater is operating (for example, a steam iron, kettle, toaster etc.).
A division of Shriro Australia Pty Ltd 104 Vanessa St Kingsgrove NSW 2208 In Australia: 1300 795 572 In New Zealand: (09) 415 6000 www.omegaaltise.