OMEGAnet® On-Line Service http://www.omega.com USA: ISO 9001 Certified Canada: Internet e-mail info@omega.com Servicing North America: One Omega Drive, Box 4047 Stamford, CT 06907-0047 Tel: (203) 359-1660 e-mail: info@omega.com 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 e-mail: info@omega.
Introduction The Digital Probe is a gauging transducer combined with conditioning electronics in a permanently connected ”smart connector” or PIE (Probe Interface Electronics). The PIE converts and corrects the output from the gauge head and transmits the result in a digital format using the Orbit protocol. Because the Digital Probe is factory calibrated using a reference Laser, the probe has a very linear output with position.
Network type Network speed Network Control Character Command Character Format Orbit - RS485 2-wire multi-drop (up to 31 per channel) 1.5Mbaud, 187.5k Baud or 9600 Baud (do not use 9600 Baud for New Applications as this will be phased out) Break Character - low (space) of >90 us (187.5k Baud) or >1.2mS (9600 Baud) 1 start, 8 data, 1 odd parity, 1 stop bit Accuracy The error quoted assumes periodic re-setting against a setting master in accordance with normal gauging practice (not less than once per day).
Gauge Head Application Information When mounting the Gauge Head in a fixture, care must be taken as the linear bearing assembly at the tip end is made to very fine tolerances. If a high force is applied to the probe casing performance may be affected. Ideally probes should be clamped in a yoke, split or collar clamp. If single point screw clamping is adopted (see diagram), then a tightening torque (in Nm) should be limited to that which will give a maximum of 50Kg point load.
Cable The Gage Head cable is custom made to achieve the optimum balance between flexibility, flex life, chemical resistance, abrasion resistance electrical and electrical screening. To minimise transducer failure due to cable damage cable runs should be positioned well clear of moving components and vulnerable working areas.
PIE and T-CON Installation GP901 M-3343 05/08
This Page Intentionally Left Blank GP901 M-3343 05/08
This Page Intentionally Left Blank GP901 M-3343 05/08
This Page Intentionally Left Blank 10 GP901 M-3343 05/08
WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation.
Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSURE, STRAIN AND FORCE Transducers & Strain Gages Load Cells & Pressure Gages Displacement Transducers Instrumentation & Accessories FLOW/LEVEL Rotameters, Gas Mass Flowmet