Specification Sheet
REVISED – March 25, 2006 submitom.doc (9/23/03)
ALUMINIZED STEEL TUBE COUPLER
INSTALLATION Aluminized Steel Construction
Swaged For Internal Connection To 0304.AS or
0404.AS Radiant tubes.
Used With Omega II
®
Radiant Tube System
Aluminized Steel, Min. 18 Ga.
Corrosion Resistant
SPECIFICATIONS
CRC Part No.:
0311.AS - 3.5” Diameter
Wt. 1.25 Lbs. (0.57 kg)
0411.AS - 4.0” Diameter
Wt. 2.0 Lbs. (0.9 kg)
Dimensions:
Minimum 18 Ga. aluminized steel, Swaged on
Both ends
Temperature Rating:
1050°F (565°C)
INSTALLATION & CHECKOUT
INSTALLATION
Install coupler as shown on shop drawing. Note
couplers are designed to fit inside the spiral radiant
tube. Apply sealer to internal surface of radiant tube
before inserting coupler. Secure with three self drilling
and taping screws on each swaged end. Refer to the
owner's manual for installation guidance.
Checkout
Make sure that the radiant tubes and couplers are
installed in accordance with the owner’s manual as
well as the shop drawing. Inspect to make sure that all
radiant tubes are securely connected, and are square
and straight.
COMBUSTION
RESEARCH
CORPORATION
Radiant Tube Couple
r
A
luminized Steel Radiant Tube Couple
r
7.75”