Owner's manual
7
Part Number Description Qty.
901002-52 O-ring ............................................................................................ 1
125501-1 Circuit Assembly Kit (10 pin connector) ..................................... 1
904005-27 Screws ........................................................................................... 6
PARTS LIST
Call OMEGA Sales Department and reference base part number (FLSC790-MA) to order
spare parts.
Symptom Probable Cause Corrective Action
No output signal 1. Incorrect or no input power Supply correct power requirements.
2. Not wired correctly Check owner’s manual for correct installation.
3. Broken connection Check resistance to determine location of
break.
4. Defective PC board connector Contact distributor or factory for replacement.
5. Defective unit Contact distributor or factory for replacement.
Signal does rise 1. Zero trimpot not set correctly Reinitiate Zero & Span adjustments - careful
above 4 mA to increase Zero read above 4 and then turn
back to 4 mA reading to avoid false 4 mA
signal.
2. No signal from meter See Turbine and Display Electronics owner’s
manual.
TROUBLESHOOTING