User’s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.
OMEGAnet ® On-Line Service omega.com Internet e-mail info@omega.com Servicing North America: Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca U.S.A.: ISO 9001 Certified One Omega Drive, Box 4047 Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com For immediate technical or application assistance: U.S.A.
FTB600B Series Ultra-Low Flow Sensors TABLE OF CONTENTS Section Page Section 1 Introduction ...................................................................... 1 A. General Description .................................................... 1 B. Principle of Operation ................................................. 1 C. Material Characteristics of PVDF ............................... 2 Section 2 Operation Parameters ..................................................... 3 A. Temperature ............
FTB600B Series Ultra-Low Flow Sensors NOTES: ii
FTB600B Series Installation 1 IMPORTANT: READ INSTRUCTIONS THOROUGHLY BEFORE INSTALLING FLOW METER Section 1 - Introduction A. General Description The FTB600B Series is an axial paddle wheel turbine type flow meter based on the pelton wheel principle. This unique patented design makes the FTB600B Series a very accurate, repeatable, linear device.
1 FTB600B Series Installation C. Material Characteristics of PVDF (Polyvinylidene Fluoride) 1. Material of construction Trade name - Kynar All wetted parts of the FTB600B Series are PVDF, excluding the O-ring. Wetted parts include any part of the meter that will or could come in contact with the fluid. List of wetted parts: 1. Barbed fittings 5. End caps 2. Flow meter body 6. Strainer 3. Rotor 7. Bearings 4. Helical nozzle (Viton O-ring seal) 2.
FTB600B Series Operating Parameters 2 Section 2. - Operating Parameters A. Temperature Since the FTB600B Series has printed circuit boards molded into the body of the meter it is strongly recommended that 180°F not be exceeded. Exceeding 180°F can cause irreparable damage to the circuit boards. B. Flow Ranges The FTB600B Series is available in six different sizes, which cover a flow range from 0.1 to 120 lpm. Specific flow ranges FTB601B 0.1 to 2 lpm (0.03 to 0.53 gpm) FTB602B 0.3 to 9 lpm (0.08 to 2.
2 4 FTB600B Series Operation Parameters
FTB600B Series Operating Parameters 2 C. Recommended Viscosity Range 1-5 cSt (w/o correction) The effects of changing viscosity on the FTB600B Series are the same as any other turbine flow meter. It is important to remember that a turbine meter is a viscosity dependent device, where as the viscosity increases the linearity of the flow meter will decrease. (Water like viscosities are ideally suited for use with the FTB600B Series) The FTB600B Series is factory calibrated with water.
3 FTB600B Series Silicone Treatment Section 3 - Silicone Treatment Silicone treatment is standard for all types of the FTB600B Series series electronics.
FTB600B Series Infrared Sensors 4 Section 4 - Infrared Sensor A. Supply Voltage 24 Vdc. Do not exceed 24 Vdc. Doing so can cause overheating and eventual failure of all PC boards. Printed circuit boards are nonrepairable. B. Frequency Output 1. Square wave pulse, unscaled (See Figure 4-1) 2. Output impedance 75 ohms 3. Directly proportional to flow rate 4. Output - dc frequency 5. Offset 0.64 volts 6. Peak voltage = Supply voltage - 1.2 volts 7. Peak to peak voltage Supply voltage - 1.2 volts - 0.
4 FTB600B Series Infrared Sensors C. Frequency Ranges for (non-cartridge models) pulses/l Model Frequency (Hz) K-Factor FTB601B 60 to 1200 36,000 FTB602B 40 to 1200 8,000 FTB603B 27 to 800 3,200 FTB604B 20 to 600 1,200 FTB605B 18.75 to 562 450 FTB606B 15 to 450 225 D. Cable Requirements 1. 20 to 22 AWG (American Wire Gauge) 2. 4 conductor-shielded cable. NOTE Avoid influences of strong electromagnetic forces as they can damage components on the PC boards.
FTB600B Series Infrared Sensors 4 Figure 4-1.
5 FTB600B Series Installation Section 5 - Installing the FTB600B Series in the fluid line. A. Make sure the fluid is compatible with PVDF (polyvinylidene fluoride) and meets viscosity, pressure and temperature parameters of the FTB600B Series. The fluid must also meet filtration requirements as listed in 3D. B. Install the FTB600B series in the fluid line with the arrow pointing in the direction of the flow. C.
FTB600B Series Installation 5 Figure 5-1.
5 FTB600B Series Installation Table 5-1.
FTB600B Series Installation 5 Table 5-1. Piping Table Con't.
6 FTB600B Series Specifications Section 6 - Specifications Accuracy: Repeatability: Linearity: Viscosity Range: Working Pressure: Wetted Materials: Power Supply: Output Signal: Pressure Drop: 14 ±3% of reading ±0.
FTB600B Series Pressure Drop Curves 7 Section 7 - Pressure Drop Curves Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB601 50 45 40 35 kPa 30 25 20 15 10 5 0 0 0.5 1.0 1.5 2.
FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB602 250 200 kPa 150 100 50 0 0 2.0 4.0 6.0 Liters/minute 16 8.0 10.
FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB603 200 180 160 140 kPa 120 100 80 60 40 20 0 0 5 10 15 Liters/minute 17
FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB604 200 180 160 140 kPa 120 100 80 60 40 20 0 0 10 20 Liters/minute 18 30
FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB605A 160 140 120 kPa 100 80 60 40 20 0 0 10 20 30 40 50 60 Liters/minute 19
FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB606A 180 160 140 120 kPa 100 80 60 40 20 0 0 10 20 30 40 50 Liters/minute 20 60 70 80 90
WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation.
Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.