Owner's manual

LDX-3A
4.0: Installation (continued)
13
M-1633/0905
To ensure the cable screen is properly connected to the LDX-3A case, an EMC cable gland should be used. This is
supplied as an extra. The diagrams below assume a single 4-way cable is being used. Remove the grommet and fit the
cable gland as shown below.
- Prepare cable as shown.
- Slide the Dome nut, sealing ring and plastic insert over cable.
- Fold and roll the screen back over itself to form a lump.
- Push cable into gland body followed by the plastic insert
(ensure anti-rotation slots engage), sealing ring and Dome nut.
- Ensure all components are properly seated before tightening
the dome nut.
10-15 mm
Screen
30 mm
125 mm
Rolled Back Screen
Dome
Nut
Sealing
Ring
Plastic
Insert
Gland
Body
Case Wall
Rotate Gland Body
to Tighten
4.7: Using an EMC Cable Gland