Owner's manual

7.0: Specifications
LDX-3A
22
M-1633/0905
7.1: Electrical
Specifications are for the LDX-3A only. Effects due to transducers are not included. Output is set to ±10Vdc into a 1k
load, unless specified differently. FRO means ‘Full Range Output’.
Parameter Value Comments
Power Supply
Mains Voltage 90 to 264 Vac
AC Input Frequency 47 to 86 Hz
AC Input Current 0.25 A (120 Vac), 0.1 A (250 Vac)
Transducer Excitation
Energising Voltage 3Vrms nominal see note 1
Energising Frequency 2.5kHz (Lo) or 5kHz (Hi) nominal
10kHz (Lo) or 13kHz (Hi)
link selectable
Half-Bridge version only
Energising Current 30mA max.
Transducer Signal Input
Input Signal Range Standard 400 to 2500mV FR 6 gain ranges (applies to LVDT only)
Special
DIV2 2500 to 500mV FR
x2 150 to 400mV FR
x4 55 to 150mV FR
see note 2
Input Load Resistance 2, 10, 10k link selectable
Options Forward and Reverse
LVDT Input
Half-Bridge Input
link selectable
standard
special plug wiring or half-bridge version only