Drainage 
Whenever the water tank is full, the unit is unbalanced or the water tank is not 
positioned properly, the compressor will stop and: 
•  The 
will flash indicating water full. 
•  The water level window will turn into red. 
•  The unit will buzz. To cancel the buzz, turn the unit off by pressing the ON/OFF 
button. 
To remove the water tank, use the 
handle to pull the tank out squarely 
from the unit. 
After empting, replace the water tank. 
The tank will need to be properly 
positioned in order for the 'water full' 
sign to cancel and your dehumidifier 
will start operating. 
Continuous Drainage 
When the dehumidifier is operated at very high humidity levels, the water tank will 
require more frequent drainage. In this situation, it may be more convenient to set 
the unit up for continuous drainage with the following procedures: 
1.  Cut the outlet at the unit back (see below). 
Caution: When the outlet is cut off, 
the said portion would be left as a hole and cannot be covered by any plug, as 
this will prevent the drainage water from reaching the water tank. 
2.  Connect the drain hole with a water tube of inner diameter 12mm. 
3.  Ensure the water will always drain away freely and the tube will remain in 
place. Note! In very cold weather conditions, precautions should be taken to 
prevent the water tube from freeing. 
Water tube of inner 
diameter 12 mm is 
required. Please note, the 
tube is not supplied with 
the unit. 