User's Manual

Getting Started
15
‘Ensure engine is running and up to temp., press to continue, or press to abort’.
‘HC HANGUP Ensure the exhaust probe is in clean air, press to continue.
HC HANGUP’ ‘HC residue check’, ‘Please wait’, Lim: 20ppm HC: XX’, ‘XXsecs’, press
- to abort. On completion of the countdown the screen will briefly display ‘HC
residue check passed.’
The base station will automatically carry out a ZERO CALIBRATION, on completion
the progress bar will be replaced briefly by ‘Passed’.
On completion there is a prompt to ‘INSERT PROBE’.
HC HANGUP
Ensure the exhaust
probe is in clean
air
-OK
HC HANGUP
HC residue check
Please wait . . . .
Limit: 20ppm HC: 00
9 secs X-Abort
X
ZERO CALIBRATION
Please wait . . .
INSERT PROBE
Exhaust probe check.
Please wait . . . .
-Continue X-Abort
X