User's Manual

Getting Started
32
the test, so that the correct parameters can be set. At the end of the test, before
saving the results you will be prompted for vehicle make, year etc. If the test is being
carried out on the last vehicle tested then fuel type, vehicle make and year etc. will
have already been saved by the handset and will be automatically added to the test
result if it is chosen to be saved.
The test limits to be applied can be selected from the next menu screen. Simply scroll
down and press . Note ASM (Custom 1) and ASM (Custom 2) limits can be edited
to suit testing requirements using PC Analyzer Software – see ‘Tests’, page 61
detailed in the PC Analyzer Software section of this manual.
Test limits are displayed. Press to proceed or X to go back to Limit Menu screen
to select other limits.
Remaining memory screen will be displayed. Note the ASM can require up to a
minute and a half to complete.
The handset will then detail the same preconditioning , HC hang , Zero Calibration as
in other test routines before displaying:
TEST LIMITS
ASM (Default)
ASM (Custom 1)
ASM (Custom 2)
TEST LIMITS
HC = 150ppm
CO = 1.50%
NOx= 1000ppm
-OK, X-Go back
DEFAULT ASM
Remaining Memory:
54mins 56 secs
-OK, X-Cancel