Leak Test - Follow on screen instruction to check integrity of water trap and probe.
Manual HC Hangup - Follow the on screen instructions to clear the system of
residual HC gas.
Display PEF - Displays the current Petrol Equivalent Factor.
Environmental Data - This function is for use by a calibration engineer and has no
user functionality.
O
2
Cell Functions - There are two items:
Oxygen Cell Value
Displays the output sensor voltage in mV
Renew Oxygen Cell
This resets the cell error code and recalibrates the analyzer with the new cell
(see ‘Oxygen cell replacement procedure’, page 75)
Zero Calibration - Follow the on screen instructions to zero the measurement gases
by reading fresh air.
Base Stn Battery - Displays current base station battery level and whether or not it
is being charged 0 for off charge, >200 if on charge.
Bench Data - Provides data about the gas bench, has no user functionality.
4/5-gas setup - This indicates whether or not a NOx sensor has been fitted, which
will determine if the CAT simulated test is activated.
BENCH PEF VALUE
0.533
-OK
BENCH DATA
ID: 01 S/W Rev: X4
SerNum: 0000196
Date: Oct 12 2007
-OK
BUILD STATE
Bench is 5-Gas
(NOx cell fitted)
-OK