OMNIFILTER IN-FF-500-SG-QC-4 QUICK CHANGE WATER DISPENSER/ ICEMAKER FILTER INSTALLATION AND OPERATION MANUAL pentair.
SPECIFICATIONS Temperature Range: 40–100°F (4.4–37.8°C) Pressure Range: 30–125 psi (2.1–8.62 bar) Service Flow Rate: 0.5 gpm (1.9 Lpm) Dimensions: 2.9" x 11.25" (73.
2. Cutting or Disconnecting the Tubing Use a 7 to 8-foot coil (3 coils, approximately 10-inch diameter) of plastic, copper or flexible hose between the outlet of the filter and the refrigerator. Determine the length of plastic, copper or flexible hose needed to connect the inlet and outlet of filter. Using a pipe cutter or hacksaw for copper tubing or utility knife for plastic, cleanly cut tubing or disconnect flexible hose from refrigerator.
TROUBLESHOOTING REPLACEMENT PARTS NOTE: Spent adsorption media will not be regenerated and used. NOTE: If adsorption media is affected by chlorine, water supply should be treated to remove chlorine prior to entering filter. Leaks between head and cartridge: A. Turn off water supply and press the red pressure-relief button. Remove bottom of housing.