Instructions / Assembly
ENGLISH
• 6 •
Model CBF1 Series A
Substance
Inuent Challenge
Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42
Chlorine 2.0 mg/L ± 10% ≥50% 97.5%
Particulates
(0.5–<1µm) - Class I
at least 10,000
particles/mL
≥85% 96%
Standard 53
Cysts Minimum 50,000/L 99.95% 99.99% 99.99%
Flow rate = 1 gpm (3.8 Lpm) Capacity = 1,000 gallons (3,800 L) or 12 months
Testing was performed under standard laboratory conditions, actual performance may vary.
CBF3: Organic Chemicals Included by Surrogate Testing
Substance
Inuent Challenge
Concentration mg/L
Maximum permissible
product water
concentration mg/L
Alachor 0.050 0.001
Atrazine 0.100 0.003
Benzene 0.081 0.001
Carbofuran 0.190 0.001
Carbon tetrachloride 0.078 0.0018
Chlorobenzene 0.077 0.001
Chloropicrin 0.015 0.0002
2,4-D 0.110 0.0017
Dibromochloropropane (DBCP) 0.052 0.00002
O-dichlorobenzene 0.080 0.001
P-dichlorobenzene 0.040 0.001
1,2-Dichloroethane 0.088 0.0048
1,1-Dichloroethylene 0.083 0.001
Cis-1,2-dichloroethylene 0.170 0.0005
Trans-1,2-dichloroethylene 0.086 0.001
1,2-Dichloropropane 0.080 0.001
Cis-1,3-dichloropropylene 0.079 0.001
Dinoseb 0.170 0.0002
Endrin 0.053 0.00059
Ethylbenzene 0.088 0.001
Ethylene dibromide (EDB) 0.044 0.00002
Haloacetonitriles (HAN):
Bromochloroacetonitrile
Dibromoacetonitrile
Dichloroacetonitrile
Trichloracetonitrile
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
Haloketones (HK):
1,1-Dichloro-2-propanone
1,1,1-Trichloro-2-propanone
0.0072
0.0082
0.0001
0.0003
Heptachlor 0.25 0.00001
Heptachlor epoxide 0.0107 0.0002
Hexachlorobutadiene 0.044 0.001
Hexachlorocyclopentadiene 0.060 0.000002
Lindane 0.055 0.00001
Methoxychlor 0.050 0.0001
Pentachlorophenol 0.096 0.001
Simazine 0.120 0.004
Styrene 0.150 0.0005
1,1,2,2,-Tetrachloroethane 0.081 0.001
Tetrachloroethylene 0.081 0.001
Toluene 0.078 0.001
2,4,5-Tp (silvex) 0.270 0.0016
Tribromoacetic acid 0.042 0.001
1,2,4-Trichlorobenzene 0.160 0.0005
1,1,1-Trichloroethane 0.084 0.0046
1,1,2-Trichloroethane 0.150 0.0005
Trichloroethylene 0.180 0.0010
Trihalomethanes (includes):
chloroform (surrogate chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.300 0.015
Xylenes (total) 0.070 0.001
Model CBF3 Series B
Substance
Inuent Challenge
Concentration
Maximum
Permissible
Product Water
Reduction
Requirements Minimum Average
Standard 42
Chlorine 2.0 mg/L ± 10% ≥50% 97%
Particulates
(0.5–<1µm) - Class I
at least 10,000
particles/mL
≥85% 97.49%
Standard 53
Cysts Minimum 50,000/L 99.95% 99.98% 99.99%
Asbestos
10
7
to 10
8
fibers/L
> 10 micrometers
in length
99% 99.82% 99.82%
Lead (pH 6.5) 0.15 mg/L 0.010 mg/L 99.3% 99.3%
Lead (pH 8.5) 0.15 mg/L 0.010 mg/L 99.3% 99.3%
Mercury (pH 6.5) 0.006 mg/L 0.002 mg/L 96.4% 96.4%
Mercury (pH 8.5) 0.006 mg/L 0.002 mg/L 96.5% 96.5%
Chloroform (VOC
surrogate)
0.300 mg/L
± 10%
0.015 mg/L 95.8% 99%
Methyl tert-butyl
ether
0.015 mg/L
± 20%
0.005 mg/L 79.39% 90%
Flow rate = 0.5 gpm (1.89 Lpm), Capacity = 400 gallons (1,514 L) or 6 months
Testing was performed under standard laboratory conditions, actual performance may vary.
Test Conditions
Flow Rate = as noted for filter system
Inlet Pressure = 60 psi (4.1 bar)
pH = 7.5±1
Temperature = 68°F ± 5°F (20°C ± 2.5°C)
Operating Requirements
Pressure = 30-125 psi (2.1–8.62 bar)
Temperature = 40-100°F (4.4–37.8°C)
Turbidity = 5 NTU Max.
PERFORMANCE DATA
Model CBF1 Series A and CBF3 Series B
Important Notice: Read this performance data and compare
the capabilities of this system with your actual water treatment
needs. It is recommended that, before installing a water treatment
system, you have your water supply tested to determine your
actual water treatment needs.
This system has been tested according to NSF/ANSI 42 and 53 for
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42 and 53.
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate disinfection
before or after the system. Systems certified for cyst reduction
may be used on disinfected waters that may contain
filterable cysts.
NOTE: The contaminants or other substances removed or
reduced by this water treatment device are not necessarily in your
water. Filter must be maintained according to manufacturer’s
recommendations, including replacement of filter cartridges.