User Manual

3.4.4 Enabling/Disabling Soft-switch Reload
The Soft-switch Reload function controls the configurations of the 2FXM and other iConverter modules
managed by the 2FXM following a power up.
When the Soft-switch Reload is disabled, the configurations of the 2FXM and the other managed modules
(non-management modules) are determined by their hardware DIP-switch settings following a return of
power.
When the Soft-switch Reload is enabled, the configurations of the 2FXM and the other managed modules
are determined by the previous software settings stored in the FLASH memory of the 2FXM following a
return of power. Each of the hardware DIP-switch settings on the module are ignored until a change is
made to the DIP-switch, then the hardware settings will take effect.
To set the Soft-switch Reload function, select 8 at the IP and Control Preferences screen, press <ENTER>
and then follow the screen prompts to change the setting.
PI SA
IP and Control Preferences Screen iConverter, Serial Agent
1: Set IP 192.168.1.220
2: Set Subnet Mask 255.255.255.0
3: Set Gateway 192.168.1.1
4: Chassis Number 1
5: Chassis Name (also sysName) 2FXM
6: Enable/Disable TELNET Enabled
7: Enable/Disable FTP Disabled
8: Enable/Disable Soft Switch Reload Disabled
9: TELNET Password *****
10: FTP Password
11: Serial Password
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then
select 6 and press <ENTER> to Save Preference Changes.
Page 19