User`s manual
00041723.DOC, Version 1.1
16/19
15 Output REC(ORD)
Stereo output (RCA) for connecting a recording unit. The
recording level is independent of the master control.
16 Master output
Stereo master output (6.3 mm jack) for connecting you
r
PA amplifier.
17 AC connection
Plug in the supplied power cable here.
18 Fuse holder/voltage setting
• Before replacing the fuse disconnect the unit from the
mains. Only use fuses of the same rating and power.
The correct fuse value is specified on the rear panel.
• The fuse holder can be switched to one of two
positions, i.e. 230 V and 115 V. The default setting is
230 V.
10 Mono inputs
XLR jacks for the mono channels MIC 1-3 for connecting
microphones or units with line level.
11 Input selector MIC/LINE
Selector switch for the mono inputs MIC 1-3
• button not pressed: input switched to microphone level
• button pressed: input switched to line level
12 Dip switches
With these switches you can switch on a 12 V phantom
power separately for each of the XLR jacks. Fo
r
activating the phantom power set the individual switch to
the lower position ON.
13 Connectors SEND/RETURN
The EM-260 features a serial path for external effects
such as the OMNITRONIC FX-001. Connect the
mono output (6.3 mm jack) SEND to the input and the
stereo input LEFT/RIGHT RETURN to the output of you
r
external effects unit.
14 Line inputs
RCA jacks for the stereo channels 1-3 for connecting
units with line level outputs (e.g. CD players).
9 Level controls MIC 1-3
Level controls for the mono channels 1-3.
7 FX LOOP on/off
On/off switch for the effect loop. With the button pressed,
the effect loop is activated.
8 Overload LED CLIP
Lights up in case of overload of the input channel.