Datasheet
4
D2D Power/Door Switch
D
2
D
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2.The operating characteristics are for operation in the A direction ( ).
Precautions
★Please refer to "Basic Switches Common Precautions" for correct use.
●Mounting
• Apply operation force to the pin plunger in the direction it
operates. Applying forces laterally or from an oblique direction
may damage the pin plunger.
• Use M4 mounting screw with plane washers or spring washers
to securely mount the Switch. Tighten the screws to a torque
of 0.49 to 0.69 N·m {5 to 7 kg·cm}.
●Wiring
• It is recommended to use sleeve receptacles when connecting
with the quick connect terminals.
• Insert the receptacle straight toward the terminal.
• Applying excessive external force horizontally or vertically may
cause deformation of terminals and may damage the
housings.
●Using Micro Loads
Using a model for ordinary loads to open or close the contact of
a micro load circuit may result in faulty contact. It is
recommended to use the Switch in the operation range shown
below. The minimum applicable load is the N-level reference
value. This value indicates the malfunction reference level for the
reliability level of 60% (λ
60).
(JIS C5003)
The equation, λ
60=0.5×10
-6
/operations, indicates that the
estimated malfunction rate is less than operations
with a reliability level of 60%.
Pull-on lock model
2948RN
16
FP
*OP
*TTP
OP
TTP
10.4
25.2
30
22
±0.1
1.8
5.8
33.6
4.3
±0.05
dia.
23.6
12.4
13
6.35
±0.1
4-Quick Connect
Terminal (#250)
* In Pull-on lock operation
1.65
+0.1
dia.
0
8 dia.
A
●Screw Mounting
D2D-2000
FP
*OP
*TTP
OP
TTP
21.2
10.4
25.2
30
21.8
2.0
31.7
12.4
6.35
±0.1
4-Quick Connect
Terminal (#250)
8 dia.
40
±0.1
A
* In Pull-on lock operation
1.65
+0.1
dia.
0
●Panel Mounting
D2D-2100
Correct Use
1
2,000,000
Voltage (V)
30
24
12
5
0
1 10 100 1,000
Current (mA)
0.1
Operating
range
26 mA
160 mA
Momentary Operation (Normal Operation)
Pull-on lock Operation
Operating characteristics
Model D2D
-2000
D2D
-2100
Operating Force OF Max. (NC-OFF)
(NO-ON)
Total Travel Force TTF Max.
1.96 N
{200 gf}
2.94 N
{300 gf}
5.88 N
{600 gf}
1.96 N
{200 gf}
2.94 N
{300 gf}
5.88 N
{600 gf}
Overtravel OT Min.
4.5 mm 4.5 mm
Free Position FP Max.
Operating Position OP (NC-OFF)
(NO-ON)
Total Travel Position TTP Max.
14.3 mm
13.5±0.6 mm
12.7±0.6 mm
8.3 mm
10.3 mm
9.5±0.6 mm
8.7±0.6 mm
4.3 mm
Operating characteristics
Model D2D
-2000
D2D
-2100
Operating Force OF Max.
19.61 N
{2,000 gf}
19.61 N
{2,000 gf}
Pretravel PT Max.
Overtravel OT Min.
Movement Differential MD Max.
2 mm
0.4 mm
1.5 mm
2 mm
0.4 mm
1.5 mm
Free Position FP Max.
Operating Position OP
Total Travel Position TTP Max.
14.3 mm
15.1±0.6 mm
16.5 mm
10.3 mm
11.1±0.6 mm
12.5 mm