Datasheet

1
D
2
D
D2D
Power/Door Switch
Door Interlock Power
Switch with Minimum
Contact gap of 3 mm
Offers the minimum contact gap of 3 mm required
for power switches as standard equipment.
Safety considerations include a double return spring
and direct drive positive contact opening feature.
Pull-on lock model for easy maintenance is also
available.
RoHS Compliant
Model Number Legend
List of Models
* Refer to next page for the pull-on lock function.
Contact Form
Contact Specifications
* Please refer to "Using Micro Loads" in "Precautions" for more informa-
tion on the minimum applicable load.
Ratings
Note. The above rating values apply under the following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 30 operations/min
Mounting
Type
Contact gap
Contact form
Standard Pull-on lock *
3 mm min. 1 mm
Screw
mounting
SPST-NO+SPST-NC D2D-1000 D2D-2000
SPST-NO D2D-1001 -
SPST-NC D2D-1002 -
Panel
mounting
SPST-NO+SPST-NC D2D-1100 D2D-2100
SPST-NO D2D-1101 -
SPST-NC D2D-1102 -
DPST-NO+SPST-NC D2D-3103 -
DPST-NO D2D-3104 -
D2D-
@@
0
@
1. Construction
1: Single pole, contact gap 3 mm
2: Pull-on lock, contact gap 1 mm
3: Double pole, contact gap 3 mm
2. Mounting
0: Screw mounting
1: Panel mounting
3. Contact
0: SPST-NO+SPST-NC
1: SPST-NO
2: SPST-NC
3: DPST-NO+SPST-NC
4: DPST-NO
12 3
Item Type Standard Pull-on lock
Contact
Specification Rivet
Material Silver
Gap (standard value) 3 mm min. 1 mm
Inrush
current
NC 30 A max. 24 A max.
NO 30 A max. 24 A max.
Minimum applicable load
(reference value) *
5 VDC 160mA
Type
Item
Rated voltage
Resistive load
Standard 250 VAC 16 A
Pull-on lock model 250 VAC 10 A
SPST-NO+SPST-NC
D2D-1000 D2D-2000
D2D-1100 D2D-2100
DPST-NO+SPST-NC
D2D-3103
SPST-NO
D2D-1001
D2D-1101
DPST-NO
D2D-3104
SPST-NC
D2D-1002
D2D-1102
NC NCNONO
NO NC NONONCNO
NONO
NO NONONO
NCNC
Terminal Connection Parts (Sold Separately) Refer to "Basic Switch Common Accessories"