Datasheet
2
D2FS Ultra Subminiature Basic Switch
Ratings
Note: The rating values apply under the following test conditions.
Ambient temperature: 20 ± 2°C
Ambient humidity: 65 ± 5%
Operating frequency: 20 operations/min
Characteristics
Note: The data given above are initial values.
*1. The values are at Free Position and Total Travel Position values for pin plunger, and Total Travel Position value for lever.
Close or open circuit of the contact is 1 ms max.
*2. For testing conditions, consult your OMRON sales representative.
Rated voltage Resistive load
6 VDC 0.1 A
Operating speed
Pin plunger models: 1 mm to 500 mm/s
Lever models: 5 mm to 500 mm/s
Operatiing frequency
Mechanical
Pin plunger models: 200 operations/min max.
Lever models: 100 operations/min max.
Electrical 30 operations/min max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance (initial value) 100 mΩ max.
Dielectric strength
Between terminals of same polarity 600 VAC 50/60 Hz 1 min
Between current carrying metal parts and ground
1,500 VAC 50/60 Hz 1 min
Between each terminal and non-current carrying
metal part
Vibration resistance
Malfunction
*1
10 to 55 Hz, 1.5 mm double amplitude
Shock resistance
Destruction 1,000 m/s
2
max.
Malfunction *1 300 m/s
2
max.
Durability *2
Mechanical 100,000 operations min. (at 30 ops./min.)
Electrical 10,000 operations min. (at 30 ops./min.)
Degree of protection IP40
Ambient operatingtamperature –20 to +70°C (at 60%RH Max.) (with no icing or condensation)
Ambient operation humidity 85%RH max. (for +5 to +35°C)
Weight Approx. 0.5 g (pin plunger models)