Datasheet

3
D2HW Sealed Ultra Subminiature Basic Switch
D
2
H
W
Contact form
Contact Specifications
Ratings
Note. The above rating values apply under the following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5 %
(3) Operating frequency: 30 operations/min
Approved Safety Standard
Consult your OMRON sales representative for specific models
with standard approvals.
UL (UL1054/CSA C22.2 No.55)
Characteristics
Note. The data given above are initial values.
*1. For the pin plunger models, the above values apply for use at the free
position, operating position, and total travel position. For the lever models,
they apply at the total travel position. Close or open circuit of the contact
is 1ms max.
*2. For testing conditions, consult your OMRON sales representative.
Mounting Structure and Reference Positions for Operating Characteristics (Unit: mm)
Note. The reference positions used for Free Position (FP), Operating Position (OP), and Total Travel Position (TTP) values are as shown above for each type of
mounting.
●SPDT ● SPST-NC, (Molded Lead Wire
Models Only)
● SPST-NO, (Molded Lead Wire
Models Only)
COM
(Black)
NO
(Blue)
NC
(Red)
COM
(Black)
NC
(Red)
COM
(Black)
NO
(Blue)
Molded lead wire colors
are indicated in
parentheses.
Contact
Specification Crossbar
Material Gold alloy
Gap (standard value) 0.5 mm
Minimum applicable load (see note) 5 VDC 1mA
Rated voltage Resistive load
125 VAC 0.1A
12 VDC
24 VDC
42 VDC
2A
1A
0.5A
Model D2HW
Rated voltage Item Resistive load
125 VAC 0.1A
12 VDC 2A
Permissible operating speed
1 mm to 500 mm/s (for pin plunger models)
Permissible operating frequency
30 operations/min
Insulation resistance
100 M
Ω
min. (at 500 VDC with insulation tester)
Contact
resistance
(initial value)
Terminals
100 m
Ω
max.
Molded lead wire models
150 m
Ω
max.
Dielectric
strength
Between terminals of the
same polarity
600 VAC 50/60 Hz 1min
Between current-carrying
metal parts and ground
1,500 VAC 50/60 Hz 1 min
Between terminals and
non-current-carrying metal
parts
1,500 VAC 50/60 Hz 1 min
Vibration
resistance * 1
Malfunction
10 to 55 Hz, 1.5 mm double amplitude
Shock
resistance
Durability
1,000 m/s
2
{approx. 100G} max.
Malfunction * 1
300 m/s
2
{approx. 30G} max.
Durability * 2
Mechanical
1,000,000 operations min. (30 operations/min)
Electrical
100,000 operations min. (20 operations/min)
Degree of
protection
Terminals
IEC IP67 (excluding the terminals on terminal models)
molded lead wire models
IEC IP67
Ambient operating temperature
-40 to
+
85°C (at ambient humidity of 60% max.)
(with no icing or condensation)
Ambient operating humidity
95% max. (for +5 to +35°C)
Weight
Approx. 0.7 g (for pin plunger models with terminals)
●Without posts
D2HW-A@
●Models with Posts
D2HW-B@
Mounting Hole Dimensions (Reference)
●M3-screw Mounting Models
D2HW-C@
Mounting Hole Dimensions (Reference)
FP
OP
TTP
7
Standard Position
4
1.7 dia.
13.3
5.3
FP
OP
TTP
3
6.5
8
±0.1
1.7 dia.
Standard
Position
13.3
5.3
2.6
±0.05
5
0
ࠉ-0.2
8
±0.1
2.6
2.4
+0.1
ࠉࠉ 0
2.4
+0.1
dia. holes
0
(depth: 5 mm min.)
FP
OP
2.65
13
±0.1
TTP
3.1
+0.13
-0.03
6
6.5
Standard
Position
3.3
±0.15
dia.
18.5
1.5
0
-0.1
1.5
0
-0.1
3
0
dia.
-0.1
5.3
13
±0.1
M3 Tap
3
+0.1
dia. holes
0
(depth: 1.5 mm min.)