Datasheet

D2MQ
D2MQ
210
Specifications
Ratings
Type Silver-plated contact type Gold-plated contact type
Rated voltage Item Resistive load
30 VDC 0.5 A 50 mA
Note: The ratings values apply under the following test conditions:
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 30 operations/min
Characteristics
Operating speed
(see note 2)
0.1 mm to 0.5 m/s
Operating frequency Mechanical: 60 operations/min max.
Electrical: 30 operations/min max.
Insulation resistance 100 M min. (at 250 VDC)
Contact resistance
(initial value)
100 m max.
Dielectric strength 500 VAC, 50/60 Hz for 1 min between terminals at the same polarity
500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground
Vibration resistance
(see note 3)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note 2)
Shock resistance
(see note 3)
Destruction: 1,000 m/s
2
{approx. 100G} max.
Malfunction: 300 m/s
2
{approx. 30G} max.
Durability (see note 4) Mechanical: 30,000 operations min. (60 operations/min)
Electrical: 10,000 operations min. (30 operations/min)
Degree of protection IEC IP40
Degree of protection
against electric shock
Class I
Proof tracking index (PTI) 175
Ambient operating
temperature
–15°C to 70°C (at ambient humidity of 60% max.) (with no icing)
Ambient operating
humidity
35% to 85% (for 5°C to 35°C)
Weight Approx. 0.3 g
Note: 1. The data given above are initial values.
2. The values are for the pin plunger models. (For different models, consult your OMRON representative.)
3. Malfunction: 1 ms max.
4. For testing conditions, consult your OMRON sales representative.
Contact Specifications
Item Silver-plated
contact type
Gold-plated
contact type
Contact
Specification Rivet
Material Silver plated Gold plated
Gap (standard
value)
0.15 mm
Inrush
t
NC 0.5 A max. 0.05 A max.
current
NO 0.5 A max. 0.05 A max.
Minimum applicable load 50 mA
at 5 VDC
5 mA at 5 VDC
Contact Form
SPDT