ALL DIMENSIONS SHOWN ARE IN MILLIMETRES.
To convert millimetres into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Subminiature Basic Switch (Sealed) – D2VW
Sealed Microswitches
CAT. No. C095-E2-03D
Using Micro Loads
Using a model for ordinary loads to open or close the contact of
a miroload circuit may result in faulty contact. Use models that
operate in the following range. However, even when using micro
load models within the operating range shown below, if inrush
current occurs when the contact is opened or closed, it may
increase contact wear and so decrease durability. Therefore,
insert a contact protection circuit where necessary.
The minimum applicable load is the N-level refreence value. This
value indicates the malfunction reference level for the reliability
level of 60% (
λ
60). The equation,
λ
60 = 0.5 x 10-6/operations
indicates that the estimated malfunction rate is less than
1/2,000,000 operations with a reliability level of 60%.
Note: AV 0.75f wires are used for standard lead wire model
UL1015 AWG20 wires are used for UL/CSA approved models.
Subminiature Basic Switch (Sealed) – D2VW
Omron 08 Cat 565-773 5/10/07 15:58 Page 668