Datasheet
6
D3V Miniature Basic Switch
D
3
V
Ratings
Note 1. The above current values are the normal current values of models with a contact gap of 1 mm (gap F), which vary with the normal current values of models with
a contact gap of 0.5 mm (gap G).
Note 2. The ratings values apply under the following test conditions:
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 30 operations/min
Approved Safety Standards
Consult your OMRON sales representative for specific models with standard approvals.
UL1054 (File No. E41515)/CSA C22.2 No.55 (File No. LR21642)
EN 61058-1: 1992+A1: 1993 (License No. 40024894)
Testing conditions: 5E4 (50,000 operations), T85 (0 to 85°C) for D3V-21/D3V-01, T105 (0 to 105°C) for D3V-16/D3V-11/D3V-6
Testing conditions: 10,000 operations, T85 (0 to 85°C)
Item
Resistive load
Model Rated voltage
D3V-21
250 VAC 21 A
125 VDC 0.6 A
250 VDC 0.3 A
D3V-16
250 VAC 16 A
125 VDC 0.6 A
250 VDC 0.3 A
D3V-11
250 VAC 11 A
125 VDC 0.6 A
250 VDC 0.3 A
D3V-6
250 VAC 6 A
125 VDC 0.4 A
250 VDC 0.3 A
D3V-01
125 VAC 0.1 A
30 VDC 0.1 A
Rated voltage Model D3V-21G D3V-16 D3V-16G D3V-11 D3V-11G D3V-6 D3V-6G D3V-01
125 VAC --- 16 A, 1/2 HP 16 A, 1/2 HP 11 A, 1/2 HP 11 A, 1/2 HP 6 A, 1/4 HP 6 A, 1/4 HP 0.1 A
250 VAC 20.1 A 16 A, 1/2 HP 16 A, 1/2 HP 11 A, 1/2 HP 11 A, 1/2 HP 6 A, 1/4 HP 6 A, 1/4 HP ---
125 VDC --- 0.6 A 0.1 A 0.6 A 0.1 A --- --- ---
250 VDC --- 0.3 A --- 0.3 A --- --- --- ---
Rated voltage Model D3V-21G D3V-16 D3V-11 D3V-6 D3V-01
125 VAC --- --- --- --- 0.1 A
250 VAC 20 (4) A 16 (3) A 11 (3) A 6 (2) A ---
Rated voltage Model D3V-21G
250 VAC 21 (8) A