Datasheet

37
D6F-D MEMS 2-Axis Flow Sensor
Fig. 4. Connection Example to Link Three Sensors
Dimensions (Unit: mm)
D6F-D010A32-00
SlaveAddress 0x01
Termination: Disable
SlaveAddress 0x02
Termination: Disable
SlaveAddress 0x03
Termination: Enable
Master
Fig. 4 shows an example of multi-drop connection
when connecting three devices on the same bus.
In this case, slave address, baud rate and built-in
termination resistor of each device must be set properly.
60 dia.
Y axis (+)
Y axis (−)
X axis (−)X axis (+)
LED Display
Green: Power Indicator
Yellow: Lit when communication
* When using the fixing hole, Please do not exceed
the depth (3.6 mm) of the shaded portion.
A
7
22
30
3.2
8
7
3.2
3 dia.
Depth1.5
6.3 dia.
B
B
3.6
2.5
Cross B-B
Description A
34.7
Power switch Knob position
LEFT: ON (default)
Right: OFF
*