Datasheet

121
Text
120
Text
Characteristics
Standard Relays
Item 1 Pole 2 Poles
Contact resistance 30 mΩ max. (high-capacity type: 100 mΩ max.) 50 mΩ max.
Operate (set) time 15 ms max
Release (reset) time AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.)
Max. operating frequency Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Impulse withstand voltage 10KV 1*40µsec
Creepage (Typ) 10.0 mm
Clearance (Typ) 9.3 mm
Tracking Resistance (CTI) 175 V
Dielectric strength 5,000 VAC, 50/60 Hz for 1 min 5,000 VAC, 50/60 Hz for 1 min
between coil and contacts*; between coil and contacts*;
1,000 VAC, 50/60 Hz for 1 min 3,000 VAC, 50/60 Hz for 1 min
between contacts of same polarity between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min
between contacts of same polarity
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75mm single amplitude (1.5mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75mm single amplitude (1.5mm double amplitude)
Shock resistance Destruction: 1,000 m/s
2
Malfunction: 200 m/s
2
when energized; 100 m/s
2
when not energized
Endurance Mechanical: AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical:100,000 operations min. (at 1,800 operations/hr under rated load)
Ambient temperature Operating: -40˚C to 70˚C (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 17 g
Note: Values in the above table are initial values.
PCB Power Relay – G2R
Insulation
Distance
PCB Power Relay – G2R
Power Relays
Item General-purpose (single contact) Bifurcated contact
Number of poles 1 pole 2 poles 1 pole
Load Resistive load Inductive load Resistive load Inductive load Resistive load Inductive load
(cosϕ = 1) (cosϕ = 0.4; (cosϕ = 1) (cosϕ = 0.4; (cosϕ = 1) (cosϕ = 0.4;
L/R = 7 ms) L/R = 7 ms) L/R = 7 ms)
Rated Load 8 A at 250 VAC; 6 A at 250 VAC; 4 A at 250 VAC; 1.5 A at 250 VAC; 5 A at 250 VAC; 2 A at 250 VAC;
8 A at 30 VDC 4 A at 30 VDC 4 A at 30 VDC 2.5 A at 30 VDC 5 A at 30 VDC 3 A at 30 VDC
Rated carry current 8 A4 A5 A
Max. switching voltage 380 VAC, 125 VDC 380 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current 8 A4 A5 A
Max. switching power 2,000 VA, 1,500 VA, 1,000 VA, 375 VA, 1,250 VA, 500 VA,
240 W 120 W 120 W 75 W 150 W 90 W
Failure rate 100 mA at 5 VDC 10 mA at 5 VDC 1 mA at 5 VDC
(reference value)
Note: P level: λ
60
= 0.1 x 10
-6
/operation.
PCB/Fully Sealed Relays
Number of poles 1 pole 2 poles
Load Resistive load Inductive load Resistive load Inductive load
(cosϕ = 1) (cosϕ = 0.4; (cosϕ = 1) (cosϕ = 0.4;
L/R = 7 ms) L/R = 7 ms)
Rated Load 5 A at 250 VAC; 3.5 A at 250 VAC; 3 A at 250 VAC; 1.5 A at 250 VAC;
5 A at 30 VDC 2.5 A at 30 VDC 3 A at 30 VDC 2 A at 30 VDC
Rated carry current 5 A 3 A
Max. switching voltage 380 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current 5 A 3 A
Max. switching power 1,250 VA, 150 W 875 VA, 75 W 750 VA, 90 W 375 VA, 60 W
Failure rate 100 mA at 5 VDC 10 mA at 5 VDC
(reference value)
Note: P level: λ
60
= 0.1 x 10
-6
/operation.
Latching Relays