Datasheet
133
Text
132
Text
PCB Power Relay – G2RL
Rated voltage 5 VDC 12 VDC 24 VDC
Rated current 50.0 mA 20.8 mA 10.4 mA
Coil resistance 100 Ω 576 Ω 2,304Ω
Must operate voltage 75% max. of the rated voltage
Must release voltage 10% min. of the rated voltage
Max. voltage 180% of the rated voltage (at 23˚C)
Power consumption Approx. 250 mW
Note: Operating characteristics are measured at a coil temperature of 23˚C
■
Coils Ratings (for High-sensitivity models)
Item Standard High-capacity High-sensitivity
Number of poles 1 pole 2 poles 1 pole 1 pole
Contact material Ag Alloy (Cd free)
Load Resistive load (cosφ=1)
Rated load 12 A at 250 VAC 8 A at 250 VAC 16 A at 250 VAC 10 A at 250 VAC
12 A at 24 VDC 8 A at 30 VDC 16 A at 30 VDC 10 A at 24 VDC
(See note.) (See note.) (See note.) (See note.)
Rated carry current 12 A (See note.) 8 A (70˚C)/5 A (85˚C) 16 A (See note.) 10 A (See note.)
(See note.)
Max. switching voltage 440 VAC, 300 VDC
Max. switching current 12 A 8 A 16 A 10 A
Max. switching power 3,000 VA (4,000 VA) 2,000 VA 4,000 VA 2,500 VA
Note: Contact your OMRON representative for the ratings on fully sealed models.
Note: Values in the above table are the initial values.
■
Contact Ratings
Item Standard/High Capacity Standard High-sensitivity
Number of poles 1 pole 2 pole 1 pole
Contact resistance 100 mΩ max.
Operate (set) time 15 ms max.
Release (reset) time 5 ms max.
Max. operating frequency Mechanical:18,000 operation/hr
Electrical:1,800 operation/hr at rated load
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 5,000 VAC, 1 min between 5,000 VAC, 1 min between 5,000 VAC, 1 min between coil
coil and contacts coil and contacts and contacts
1,000 VAC, 1 min between 2,500 VAC, 1 min between 1,000 VAC, 1 min between
contacts of same polarity contacts of different polarity contacts of same polarity
1,000 VAC, 1 min between
contacts of same polarity
Impulse withstand voltage 10 kV (1.2x50 µs) between coil and contact
Vibration resistance Destruction:10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction:10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance Destruction: 1,000 m/s
2
(approx. 100 G)
Malfunction: 100 m/s
2
(approx. 10 G)
Endurance (Mechanical) 20,000,000 operations (at 18,000 operations/hr)
Ambient temperature Operating: –40˚C to 85˚C (with no icing)
Storage: –55˚C to 85˚C (with no icing)
Ambient humidity 5% to 85%
Weight Approx. 12 g
■
Characteristics
PCB Power Relay – G2RL
Power Relays
Classification Enclosure ratings Contact form
SPST-NO SPDT DPST-NO DPDT
Standard Flux protection G2RL-1A G2RL-1 G2RL-2A G2RL-2
Fully sealed G2RL-1A4 G2RL-14 G2RL-2A4 G2RL-24
High-capacity Flux protection G2RL-1A-E G2RL-1-E --- ---
Fully sealed G2RL-1A4-E G2RL-14-E --- ---
High-sensitivity Flux protection G2RL-1A-H G2RL-1-H --- ---
Ordering Information
Next-generation PCB Relay
Available in Various Models
■
ROHS compliant.
■
High sensitivity: (250mW) and high capacity
(16A) models available
■
Low profile: 15.7 mm max. in height.
■
Conforms to EN 61810-1, UL508 and
CSA22.2.
■
Meets EN60335-1 requirements
■
Creepage and clearance 10mm/10mm
■
Tracking distance: CTI>250
■
UL 1446 Class F Coil Insulation system
available.
■
5mm and 7mm terminal pitch models
available (contact Omron)
Coil Ratings (for Standard and high capacity models)
4. Classification
None: Standard
E: High-capacity (1 pole)
5. Coil Power consumption
None: Approx. 400mW (48 VDC : Approx. 430 mW)
H: Approx. 250 mW
180% of the rated voltage (at 23˚C)
Omron 08 Cat 1-302 5/10/07 15:39 Page 132