Datasheet

2
G2RL-1A-E2-CV-HA PCB Power Relay
G
2
R
L
1
A
E
2
C
V
H
A
I
I
I
I
G
2
R
L
E
2
I
Characteristics
Note: Values in the above table are the initial values at 23°C.
*1. Measurement conditions: 5 VDC, 1 A, voltage drop method
*2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter.
*3. 360 operations per hour.
Engineering Data
Classification High-capacity & High-temperature type
Item Model G2RL-1A-E2-CV-HA
Contact resistance *1 100 mΩ max.
Operate time 15 ms max.
Release time 5 ms max.
Insulation resistance *2 1,000 MΩ min.
Dielectric strength
Between coil and contacts 5,000 VAC, 50/60 Hz for 1 min
Between contacts of the
same polarity
1,000 VAC, 50/60 Hz for 1 min
Impulse withstand voltage 10 kV (1.2 × 50 µs)
Vibration resistance
Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance
Destruction 1,000 m/s
2
Malfunction Energized: 100 m/s
2
, De-energized: 100 m/s
2
Durability
Mechanical 20,000,000 operations (18,000 operation per hour)
Electrical *3
(resistive load)
100,000 operations at 250 VAC, 23 A, at 105°C (1s ON / 9s OFF)
Ambient operating temperature -40°C to 105°C (with no icing or condensation)
Ambient operating humidity 5% to 85% (with no icing or condensation)
Weight Approx. 12 g
Maximum Switching Capacity Ambient Temperature vs. Maximum Coil Voltage
Shock Malfunction Ambient Temperature vs.
Must Operate and Must Release Voltage
0
5
10
15
20
25
0 50 100 150 200 250 300
23
Switching voltage (V)
Switching current (A)
0
50
100
150
200
020 406080
100 120
23
105
180
130
Ambient Temperature (°C)
Maximum coil voltage (% of rated)
Note: The maximum coil voltage refers to the maximum value in a varying
range of operating power voltage, not a continuous voltage.
Test conditions: Shock is applied
in ±X, ±Y, and ±Z directions three
times each with without energizing
the Relays to check the number of
malfunctions.
Requirement: None malfuction
100 m/s
2
0
10
20
30
40
50
60
70
80
90
100
020406080100120
Ambient Temperature (°C)
Maximum coil voltage (% of rated)
Must operate voltage
Must release voltage
max.
min.
X
max.
min.
X