Datasheet

1
G
4
A
G4A
PCB Power Relay
Miniature Single-pole Relay with
80A Surge Current and 20A
Switching Current
Capable of Switching Motor Load of 80-A Surge Current and 20A
Switching/Cut-off Current
Miniature, relay with high switching power and long endurance.
Creepage distance conforms to UL and CSA standards.
Highly noise-resistive insulation materials employed.
Standard model available with flux protection construction.
RoHS Compliant
Model Number Legend
G4A-@@-@-@
———
12 3 4
1. Number of Poles
1: 1-pole
2. Contact Form
A: SPST-NO (1a)
Application Examples
Air conditioner
3. Terminal Shape
None : #250 quick-connect/
PCB coil terminals
P : PCB terminals/
PCB coil terminals
4. Special Function
E: For long endurance
Characteristics
Note. The data given above are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage
drop method.
*2. Measurement conditions: The insulation
resistance was measured with a 500 VDC
megohmmeter at the same locations as the
dielectric strength was measured.
*3. This value was measured at a switching
frequency of 120 operations/min.
Contact resistance *1 100 m
Ω
max.
Operate time 20 ms max.
Release time 10 ms max.
Max.
operating
frequency
Mechanical 18,000 operations/hr
Insulation resistance *2 1,000 M
Ω
min.
Dielectric
strength
Between coil
and contacts
4,500 VAC 50/60 Hz for
1min
Between
contacts of
the same
polarity
1,000 VAC 50/60 Hz for
1min
Impulse
withstand
voltage
Between coil
and contacts
8.5 kV (1.2 x 50
μ
s)
Insulation
distance
Between coil
and contacts
Clearance: 3.2 mm,
Creepage: 6.4 mm
Vibration
resistance
Destruction
10 to 55 to 10 Hz,
0.75 mm single amplitude
(1.5 mm double amplitude)
Malfunction
10 to 55 to 10 Hz,
0.75 mm single amplitude
(1.5 mm double amplitude)
Shock
resistance
Destruction 1,000 m/s
2
Malfunction 200 m/s
2
Durability
Mechanical
2,000,000 operations min.
(at 18,000 operations/hr)
Resistive
load
100,000 operations min.
(ON/OFF: 1 s)
Motor load
200,000 operations min.
(ON/OFF: 1.5 s)
Inverter load
30,000 operations min.
(ON: 3 s, OFF: 5 s)
Failure rate (P level)
(reference value *3)
100 mA at 5 VDC
Ambient operating
temperature
-20°C to 60°C (with no icing
or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 23 g
Ordering Information
Quick-connect/PCB coil terminals
PCB terminals
Ratings
Coil
Note 1. The rated current and coil resistance are
measured at a coil temperature of 23
°
C
with a tolerance of ±10%.
2. The inductances shown above are
reference values.
3. Operating characteristics are measured at
a coil temperature of 23
°
C.
4. Max. permissible voltage refers to the
maximum value in a varying range of
operating power voltage, not a continuous
voltage.
Contacts
Contact form Load Contact Terminal Coil terminal Model Rated voltage
Minimum
packing unit
SPST-NO
(1a)
#250 quick-connect
terminals
PCB terminals G4A-1A-E 12, 24 VDC 50 pcs/tray
Contact form Load Contact Terminal Coil terminal Model Rated voltage
Minimum
packing unit
SPST-NO
(1a)
PCB terminals PCB terminals G4A-1A-PE 12, 24 VDC 50 pcs/tray
Item
Rated voltage
Rated
current
(mA)
Coil
resistance
(
Ω
)
Must operate voltage
(V)
Must release voltage
(V)
Max. permissible voltage
(V)
Power consumption
(W)
% of rated voltage
12 VDC 75 160
70% max. 10% min.
160%
(at 23°C)
0.9
24 VDC 37.5 640
Load
Item
Resistive load
Contact type Single
Contact material Ag-Alloy (Cd free)
Rated load 20 A at 250 VAC
Rated carry current 20 A
Max. switching voltage 250 VAC
Max. switching current 20 A
Note. When ordering, add the rated coil voltage to the model number.
Example: G4A-1A-E DC12
However, the notation of the coil voltage on the product case as well as on the packing will be marked
as @@ VDC.
Rated coil voltage
Motor Ratings
Inverter Ratings
Overload Durability (Reference Value)
Load conditions
Switching
frequency
Electrical
durability
250 VAC:
Inrush current: 80 A,
0.3 s (cos
φ
= 0.7)
Break current: 20 A
(cos
φ
= 0.9)
ON: 1.5 s
OFF: 1.5 s
200,000
operations
Load conditions
Switching
frequency
Electrical
durability
100 VAC:
Inrush current:
200 A (0.P)
Break current: 20 A
ON: 3 s
OFF: 5 s
30,000
operations
Load conditions
Switching
frequency
Electrical
durability
250 VAC:
Inrush current: 80 A
Break current: 80 A
(cos
φ
= 0.7)
ON: 1.5 s
OFF: 99 s
1,500
operations

Summary of content (4 pages)