Datasheet

3
G4A PCB Power Relay
G
4
A
Approved Standards
The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in
this datasheet.
Precautions
Please refer to “PCB Relays Common Precautions” for correct use.
UL Recognized (File No. E41643) CSA Certified (File No. LR31928)
EN/IEC, VDE Certified (Certificate No. 107293)
Model
Number of
poles
Coil ratings Contact ratings
Number of test
operations
G4A-1A-E
G4A-1A-PE
SPST-NO
(1a)
12 to 24 VDC
20 A, 250 VAC (Resistive)
40°C
100,000
15 A, 30 VDC (Resistive)
40°C
23 A, 277 VAC (General
Purpose) 40°C
30,000
TV-15 120 V AC 40°C 25,000
Model
Number of
poles
Coil ratings Contact ratings
Number of test
operations
G4A-1A-E
G4A-1A-PE
SPST-NO
(1a)
12 to 24 VDC
20 A, 250 VAC (Resistive)
40°C
10,000
15 A, 30 VDC (Resistive)
40°C
23 A, 277 VAC (General
Purpose) 40°C
30,000
TV-15 120 V AC 40°C 25,000
Model
Number of
poles
Coil ratings Contact ratings
Number of test
operations
G4A-1A-E
G4A-1A-PE
SPST-NO
(1a)
12, 24 VDC
20 A, 250 VAC (cos
φ
=1.0)
50°C
100,000
Mounting
When mounting more than two Relays
side by side, keep a 3 mm gap
horizontally and vertically between
Relays to ensure a good heat
dissipation. It may cause a malfunction
if heat is not dissipated smoothly from
the Relay.
Terminals
The terminals fit FASTON receptacle
250 and are suitable for positive-lock
mounting. Use only Faston terminals
with the specified numbers.
Select leads for connecting Faston
receptacles with wire diameters that
are within the allowable range for the
load current.
Do not apply excessive force to the
terminals when mounting or
dismounting the Faston receptacle.
Insert and remove terminals carefully
one at a time. Do not insert terminals
at an angle, or insert/remove multiple
terminals at the same time.
Refer to the following table for
recommendations of connectors made
by OMRON.
Other Precautions
This Relay is suitable for power load
switching of air-conditioning
compressors and power supplies, etc.
Do not use the G4A to switch micro
loads less than 100 mA, such as in
signal applications.
Correct Use
Ty pe
Receptacle
terminals
Housing
#250 terminals
(width: 6.35 mm)
XT3W-S441-12
XT3W-S442-12
XT3W-S443-12
XT3B-1S white