Contact Ratings
360-mW Type
Rated voltage 5 VDC 9 VDC 12 VDC 24 VDC 48 VDC
Rated current 72 mA 40 mA 30 mA 15 mA 7.5 mA
Coil resistance 70 Ω 225 Ω 400 Ω 1,600 Ω 6,400 Ω
Must operate voltage 75% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 130% of rated voltage (at 85˚C), 170% of rated voltage (at 23˚C)
Power consumption 360 - 400mW
Note: The rated current and coil resistance are measured at a coil temperature of 23˚C with a tolerance of ±10%.
Standard G5LE-G G5LE-E/-E-36
Load Resistive load (cosφ = 1) Resistive load (cosφ = 1) Resistive load (cosφ = 1)
Rated Load 10A at 120VAC; 8A at 30VDC; 10A at 250VAC (12+24VDC) 10A at 35VDC 16A at 250VAC
Contact material AgSnO
2
(AgSnIn optional) AgSnO
2
AgSnIn
Rated Carry Current 10 A 10A 16A
Max. switching voltage 250VAC; 125VDC (30VDC when UL/USA standard is applied) 35VDC 250VAC
Max. switching current AC: 10 A; DC: 8 A DC: 10A AC: 16A
Max. switching power 1,200 VA, 240 W 350W 4000VA
Failure rate 100 mA at 5 VDC 100mA at 5VDC 100mA at 5VDC
(reference value)
Power Relays
Characteristics
Contact resistance 100 mΩ max.
Operate time 10 ms max.
Release time 5 ms max.
Bounce Time Operate: Approx. 0.6 ms
Release: Approx. 7.2 ms
Max. switching frequency Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr at rated load
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
1,500VAC (for suffix -G) 50/60Hz for 1 min between contacts of same polarity
Impulse withstand voltage 4,500 V (1.2 50 µs) between coil and contacts
Creepage (Typ) 3.3 mm
Clearance (Typ) 2.7 mm
Tracking Resistance (CTI) 250 V
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance Destruction: 1,000 m/s
2
Malfunction: 100 m/s
2
Endurance Mechanical: 10,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr) (for standard type)
36,000 operations min. (10 A at 250 VAC)
100,000 operations min (at 1,800 operations/hr, 12A 250VAC) - applicable for G5LE-1-E
normally open contact only)
Ambient temperature Operating: -40˚C to 85˚C (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 12 g
Insulation
Distance
Rated voltage 9VDC 12VDC 20VDC 24VDC
Rated current 77.8mA 58.3mA 35.0mA 29.2mA
Coil resistance 115.7 Ω 205.7 Ω 571.4 Ω 822.9 Ω
Must operate voltage 75% of rated voltage (max)
Must release voltage 10% of rated voltage (min)
Max. voltage 120% of rated voltage at 85ºC, 150% of rated voltage at 23ºC
Power consumption Approx 700mW
Note: The rated current and coil resistance are measured at a coil temperature of 23˚C with a tolerance of ±10%.
Coil Ratings
700-mW Type (G5LE-G)
400-mW Type
Rated voltage 5 VDC 9 VDC 12 VDC 24 VDC 48 VDC
Rated current 79.4 mA 45 mA 33.3 mA 16.7 mA 8.33 mA
Coil resistance 63 Ω 200 Ω 360 Ω 1,440 Ω 5,760 Ω
Must operate voltage 75% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 130% of rated voltage at 85˚C, 170% of rated voltage at 23˚C
Power consumption Approx. 400 mW
Note: The rated current and coil resistance are measured at a coil temperature of 23˚C with a tolerance of ±10%.
Specifications
PCB Power Relay – G5LE
Model Number Legend
1. Number of Poles
1: 1 pole
2. Contact Form
None: SPDT
A: SPST-NO
3. Enclosure ratings
None: Flux protection
4: Fully sealed
(not applicable with -E and -G versions)
4. Contact Material
None: AgSnO
2
(AgSnIn for -E and -G versions)
ASI: AgSnIn
5. Insulation System
None: Class B
(Class F for -E and -G versions)
CF: Class F (UL and CSA only)
6. Coil Power Consumption/Coil Characteristic
None: Approx. 400 mW
(Approx 700mW applicable with -G versions)
36: Approx. 360 mW
(not applicable for -G version)
7. Classification
G: 0.8mm contact gap type
E: High capacity type
8. Approved Standards
None: UL, CSA, TÜV
VD: UL, CSA, TÜV and VDE
(Not applicable with “-CF.”, -E and -G version)
9. Packaging
None: Standard polystyrene tray
SP: Anti-static tube packaging
10. Rated Coil Voltage
5, 9, 12, 24, 48 VDC
Rated coil voltage
Note: When ordering, add the rated coil voltage to the model number.
Example: G5LE-1 12 VDC
Omron 08 Cat 1-302 5/10/07 15:39 Page 92