Datasheet

95
Text
94
Text
PCB Power Relay – G5LE
Engineering Data
Maximum Switching Power
G5LE
Ambient Temperature vs.
Maximum Coil Voltage
Maximum coil voltage (%)
Ambient temperature (°C)
Switching voltage (V)
Endurance
G5LE
Endurance (x10 operations)
3
Switching current (A)
Switching current (A)
AC re
sistive
load
DC resistive
load
23
30-VDC
resistive load
120-VAC
resistive load
30-VDC
inductive
(L/R=7 ms)
120-VAC
inductive
cosφ=0.4
(see note)
2 4 6 8 10 12
Note: Same curve as for 250-VAC
resistive load
200
180
160
140
120
100
0
-25 20 30 40 50 60 70 80 90 100
10
7
5
3
1
0.7
0.5
0.3
0 10 30 50 125 250 500 1,000
5,000
3,000
1,000
700
500
30
0
300
100
70
50
0
Note: The maximum coil voltage refers to the
maximum value in a varying range of
operating power voltage, not a continu-
ous voltage.
For standard type
For suffix -E and -G
PCB Power Relay – G5LE
EN 61810-1, EN 60255, IEC (VDE TUV Reg No. R9151267,
VDE Reg No. 6850UG)
Model Coil ratings Contact ratings
G5LE Approx. 400 mW 10A, 250 VAC (resistive load 50,000 cycles at 85°C)
3, 5, 6, 9, 12, 24, 48 VDC 5A, 30VDC
Approx. 360 mW 2.5A, 250VAC (cosφ = 0.4)
5, 6, 12, 24, 48 VDC
Model Coil ratings Contact ratings
G5LE 3 to 48 VDC 12 A, 120 VAC (resistive load 30,000 cycles)
10 A, 250 VAC (general use)
10 A, 125 VAC (general use 100,000 cycles)
8 A, 30 VDC (resistive load)
6 A, 277 VAC (general use)
NO:
1/6 hp, 120 VAC (50,000 cycles)
1/3 hp, 125 VAC, 70˚C 30K with Class 130B system
65°C 30K with Class 105 Coil insulation system
TV-3, 120 VAC
TV-5, 120 VAC (For ASI only)
NC:
1/8 hp, 120 VAC (50,000 cycles)
1/10 hp, 120 VAC (50,000 cycles))
Approved Standards
UL508, UL114, UL478, UL325, UL873, UL1409, UL1950 (File No. E41643)/CSA
C22.2 No. 14, No. 1 (File No. LR34815)
Power Relays
Omron 08 Cat 1-302 5/10/07 15:39 Page 94