Datasheet
5
G5NB PCB Power Relay
G
5
N
B
■Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values
before use.
●UL Recognized: (File No. E41515)
CSA Certified:
(File No. LR31928)
●EN/IEC, VDE Certified (Certificate No. 137575)
Model Contact form Coil ratings Contact ratings
Number of test
operations
G5NB-1A(4)(-HA)(-CF)(-PW)
SPST-NO
(1a)
5 to 24V DC
3A 250V AC (Resistive) 85°C 100,000
3A 30V DC (Resistive) 70°C 6,000
G5NB-1A(4)-E
G5NB-1A-E-HA
5A 250 V AC (Resistive) 85°C
5A 30 V DC (Resistive) 70°C
6,000
Model Contact form Coil ratings Contact ratings
Number of test
operations
G5NB-1A(4)(-HA)(-CF)(-PW)
SPST-NO
(1a)
5, 12, 18, 24V DC
3A 250V AC (Resistive) 85°C
3A 30V DC (Resistive) 85°C
100,000
G5NB-1A(4)-E
G5NB-1A-E-HA
5A 250 V AC (Resistive) 85°C
5A 30 V DC (Resistive) 85°C
10,000
3A 250V AC (Resistive) 85°C 100,000
Creepage distance 6.0 mm min.
Clearance distance 6.0 mm min.
Insulation material group IIIa
Type of insulation coil-contact circuit
open contact circuit
Pollution degree 2 / Reinforced (Sealed)
Pollution degree 3 / Basic (Flux protection) / Reinforced (Sealed)
Micro disconnection
Rated Insulation voltage 250 V
Pollution degree 3
Rated voltage system 250 V
Over voltage category III
Category of protection according to IEC 61810-1 RT II (Flux protection) / RT III (Sealed)
Glow wire according to IEC 60335-1
<HA Models only>
GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)
Tracking resistance according to IEC 60112 PTI 250 V min. (housing parts)
Flammability class according to UL94 V-0