■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
●Coil Voltage Reduction (Holding Voltage) after Relay
Operation
• If the coil voltage is reduced to the holding voltage after Relay
operation, first apply the rated voltage to the coil for at least
100 ms, as shown below.
• A voltage of at least 40% of the rated voltage is required for
the coil holding voltage. Do not allow voltage fluctuations to
cause the coil holding voltage to fall below this level.
* The coil resistance were measured at a coil temperature of 23°C with
tolerances of ± 10%.
Correct Use
Applied
coil voltage
Coil resistance*
Power
consumption
Rated voltage 100%
125Ω (5 VDC)
720Ω (12 VDC)
2880Ω (24 VDC)
Approx. 200 mW
Holding voltage 40% Approx. 32 mW
40%
(Holding voltage)
100%
(Rated voltage)
100ms min.