Datasheet
4
G5NB-EL PCB Power Relay
G
5
N
B
-
E
L
■Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values
before use.
●UL Recognized: (File No. E41515)
CSA Certified:
(File No. LR31928)
●EN/IEC, VDE Certified
(Certificate No. 137575)
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
●Coil Voltage Reduction (Holding Voltage) after Relay
operation
• If the coil voltage is reduced to the holding voltage after Relay
operation, first apply the rated voltage to the coil for at least
100 ms, as shown below.
• A voltage of at least 50% of the rated voltage is required for
the coil holding voltage. Do not allow voltage fluctuations to
cause the coil holding voltage to fall below this level.
* The coil resistance were measured at a coil temperature of 23°C with
tolerances of ±10%.
Model Contact form Coil ratings Contact ratings
Number of test
operations
G5NB-1A4-EL-HA(-PW)
G5NB-1A-EL-HA-A85
SPST-NO
(1a)
5 to 24V DC
7A 250V AC (General Purpose) 85°C 30,000
5A 250V AC (General Purpose) 85°C 50,000
5A 30V DC (Resistive) 85°C 6,000
Model Contact form Coil ratings Contact ratings
Number of test
operations
G5NB-1A4-EL-HA(-PW)
G5NB-1A-EL-HA-A85
SPST-NO
(1a)
5, 12, 24V DC
7A 250V AC (Resistive) 85°C
10,000
5A 30V DC (Resistive) 85°C
Correct Use
Applied
coil voltage
Coil resistance*
Power
consumption
Rated voltage 100%
125Ω (5 VDC)
720Ω (12 VDC)
2880Ω (24 VDC)
Approx.200 mW
Holding voltage 50% Approx.50 mW
50%
(Holding voltage)
100%
(Rated voltage)
100ms min.