Datasheet

3
G5NB-EL PCB Power Relay
G
5
N
B
-
E
L
Engineering Data
Dimensions (Unit: mm)
Maximum Switching Capacity Durability
Ambient Temperature vs. Maximum Coil Voltage
Shock malfunction
Switching voltage (V)
Switching current (A)
10
7
5
1
0.1
1 10 30 100 250 1,000
AC resistive
load
DC resistive
load
Durability (10
4
operations)
Switching current (A)
100
50
30
10
5
3
1
0 1 2 3 4 5 6 7
250V AC resistive load
30V DC resistive load
Maximum coil voltage (%)
Ambient temperature (°C)
200
180
160
140
120
100
80
60
40
0 20 23 40 60 80 85 100
7A current
Test Item: G5NB-1A4-EL-HA 24 VDC
Number of Relays: 5 pcs.
Z
Z
Z'
Z'
Shock direction
Unit: m/s
2
Y
Y
Y'
Y'
X
X
X'
X'
1,000
1,000
1,000
1,000
1,000 1,000
Energized
De-energized
700
125
Test Item: G5NB-1A4-EL-HA 24 VDC
Number of Relays: 5 pcs
Test Method: Shock is applied 3
times in 6 directions along 3 axes
and the level at which shock caused
malfunction is measured. The
energized voltage should be 100% of
the rated voltage.
Rating: 100 m/s
2
7 11.5
20.5max.
(20.4)*
15.3max.
(15.0)*
7.2max.
(7.0)*
4.7
(1.05)
(1.15)
Four, 1.1 dia.
2 1
4
3
3.4
@0.4
11.5 7
0.27 0.33
0.8
4.7
*Average value
G5NB-1A4-EL-HA(-PW)
G5NB-1A-EL-HA-A85
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
(No coil polarity)
Terminal Arrangement/
Internal Connections
(Bottom View)