■ Coil Ratings
Note: 1. The above items are measured at a coil temperature of 23°C.
2. The tolerance of the rated current is +10%.
3. Please use the diode for serge absorption for a coil.
■
Contact Ratings
Note: P level: λ
60
= 0.1 × 10
–6
operations
■
Characteristics
Note: 1. Values in the above table are initial values.
2. The contact resistance is measured with 1 A applied at
5 VDC using a fall-of-potential method.
3. The insulation resistance is measured between coil
and contacts and between contacts of the same polar-
ity at 500 VDC.
4. The release time is value with a diode attached.
Silent Models: G5RL-1A(-E)-LN
Rated voltage 5 VDC 12 VDC 24 VDC
Rated current 106.0 mA 44.2 mA 22.1 mA
Coil resistance 47.2
Ω 272 Ω 1,086 Ω
Must operate voltage 70% of rated voltage
Must release voltage 10% of rated voltage
Max. voltage 110% of rated voltage
Power consumption Approx. 530 mW
Item Standard High capacity
Contact form SPST-NO SPST-NO
Contact material Ag alloy (Cd free)
Load Resistive load (cos
φ=1)
Rated load 12 A at 250 VAC
12 A at 24 VDC
16 A at 250 VAC
16 A at 24 VDC
Rated carry
current
12 A 16 A
Max. switching
voltage
250 VAC, 24 VDC
Max. switching
current
12 A 16 A
Max. switching
power
3,000 VA, 288 W 4,000 VA, 384 W
Failure rate
(reference value)
100 mA at 5 VDC
Item Standard High capacity
Contact resistance 100 m
Ω max.
Operate time 15 ms max.
Release time 15 ms max.
Insulation
resistance
1,000 M
Ω min. (at 500 VDC)
Dielectric strength 6,000 VAC, 50/60 Hz for 1 min between
coil and contacts
1,000 VAC, 50/60 Hz for 1 min between
contacts of same polarity
Impulse withstand
voltage
10 kV between coil and contacts (1.2
×
50 µs)
Vibration
resistance
Destruction: 10 to 55 to 10 Hz, 1.5-mm
double amplitude
Malfunction: 10 to 55 to 10 Hz, 1.5-mm
double amplitude
Endurance Mechanical:
1,000,000 opera-
tions min.
(at 18,000 opera-
tions/h.)
Electrical:
100,000 opera-
tions min.
(Resistive load,
12 A, 250 VAC)
(Resistive load,
12 A, 24 VDC)
Mechanical:
1,000,000 opera-
tions min.
(at 18,000 opera-
tions/h.)
Electrical:
50,000 operations
min.
(Resistive load,
16 A, 250 VAC)
(Resistive load,
16 A, 24 VDC)
Ambient
temperature
Operating:
−40°C to 85°C (with no icing)
Ambient humidity Operating: 5% to 85%