Datasheet
187
Text
186
Text
PCB Signal Relay – G5V-1
■
Contact Ratings
Load Resistive load (cosϕ = 1)
Rated Load 0.5 A at 125 VAC; 1 A at 24 VDC
Contact Material Ag (Au alloy)
Rated Carry Current 2 A
Max. switching voltage 125 VAC, 60 VDC
Max. switching current 1 A
Max. switching power 62.5 VA, 30 W
Failure rate (reference value) 1 mA at 5 VDC
Note: P level: λ
60
= 0.1 x 10
-6
/operation.
This value was measured at a switching frequency of 120 operaions/min and the criterion of contact resistance is 100. This
value may vary depending on the operating environment. Always double-check relay suitability under actual operating
conditions.
■
Characteristics
Contact resistance (see note 1)
100 mΩ max.
Operate time (see note 2) 5 ms max. (mean value: approx. 2.5 ms)
Release time (see note 2) 5 ms max. (mean value: approx. 0.9 ms)
Max. operating frequency Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr at rated load
Insulation resistance (see note 2)
1,000 MΩ min. (at 500 VDC between coil and contacts, at 250 VDC between contacts of same polarity.)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between coil and contacts
400 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage 1,500 V (10 x 160 µs) between coil and contacts (conforms to FCC Part 68)
Vibration resistance Destruction: 10 to 55 to 10 Hz, 1.65mm single amplitude (3.3mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 1.65mm single amplitude (3.3mm double amplitude)
Shock resistance Destruction: 1,000 m/s
2
Malfunction: 100 m/s
2
Endurance Mechanical: 5,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (under rated load, at 1,800 operations/hr)
Ambient temperature Operating: -40°C to 70°C (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 2 g
Note: 1. The contact resistance was measured wih 10mA at 1VDC with a voltage drop method.
2. Values in parantheses are actual values.
3. The insulation resistance was measured with a 500VDC megohmeter between coil and contacts with a 250VDC megohmeter
between contacts with the same polarity applied to the same parts as those used for checking the dielectric strength.
Model Contact form Coil ratings Contact ratings
G5V-1 SPDT 3 to 24 VDC 0.5 A, 125 VAC (general use)
0.3 A, 110 VDC (resistive load)
1 A, 30 VDC (resistive load)
■
Approved Standards
UL (File No. E41515)/CSA C22.2 No.0, No.14 (File No. LR31928)
Signal Relays
Ultra-miniature, Highly Sensitive
SPDT Relay for Signal Circuits
■
ROHS compliant.
■
Ultra-miniature at 12.5 x 7.5 x 10 mm
(L x W x H).
■
Wide switching power of 1 mA to 1 A.
■
High sensitivity: 150mW nominal coil power.
■
Fully sealed construction.
■
International 2.54mm terminal pitch.
■
Conforms to FCC Part 68 requirements for
coil to contacts.
Specifications
Rated coil voltage
Note: When ordering, add the rated coil voltage to the model number.
Example: G5V-1 12 VDC
Model Number Legend
1. Contact Form
1: SPDT
2. Rated Coil Voltage
3, 5, 6, 9, 12, 24 VDC
G5V - VDC
12
Classification Model
Contact form Contact type Contact material Structure
SPDT Single crossbar AG (Au Alloy) Fully sealed G5V-1
■
Coil Ratings
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC
Rated current 50 mA 30 mA 25 mA 16.7 mA 12.5 mA 6.25 mA
Coil resistance 60 Ω 167 Ω 240 Ω 540 Ω 960 Ω 3,840 Ω
Coil inductance Armature OFF
0.05 0.15 0.20 0.45 0.85 3.48
(H) (ref. value) Armature ON
0.11 0.29 0.41 0.93 1.63 6.61
Must operate voltage 80% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 200% of rated voltage at 23°C
Power consumption Approx. 150 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest that can be imposed on the relay coil.
Ordering Information
PCB Signal Relay – G5V-1
Omron 08 Cat 1-302 5/10/07 15:39 Page 186