Datasheet
2
G5V-1 Low Signal Relay
G
5
V
-
1
■Characteristics
Contact resistance *1 100 m
Ω
max.
Note: The values here are initial values.
*1. Measured with 10 mA at 1 VDC with a voltage drop
method.
*2. Measured with a 500 VDC megohmmeter between
coil and contacts and a 250 VDC megohmmeter
between contacts with the same polarity applied to
the same parts as those used for checking the
dielectric strength.
*3. This value was measured at a switching frequency
of 120 operations/min and the criterion of contact
resistance is 100 Ω.
This value may vary depending on the switching
frequency and operating environment. Always
double-check relay suitability under actual operating
conditions.
Operate time 5 ms max.
Release time 5 ms max.
Insulation resistance *2
1,000 M
Ω
min. (at 500 VDC between coil and contacts,
at 250 VDC between contacts of same polarity.)
Dielectric
strength
Between coil and contacts 1,000 VAC, 50/60 Hz for 1 min
Between contacts of the same polarity 400 VAC, 50/60 Hz for 1 min
Vibration
resistance
Destruction
10 to 55 to 10 Hz, 1.65 mm single amplitude
(3.3 mm double amplitude)
Malfunction
10 to 55 to 10 Hz, 1.65 mm single amplitude
(3.3 mm double amplitude)
Shock
resistance
Destruction 1,000 m/s
2
Malfunction 100 m/s
2
Durability
Mechanical 5,000,000 operations min. (at 36,000 operations/hr)
Electrical
100,000 operations min.
(under rated load, at 1,800 operations/hr)
Failure rate (P level) (reference value) *3 1 mA at 5 VDC
Ambient operating temperature
-40°C to 70°C (Standard), -40°C to 90°C (G5V-1-T90)
(with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 2 g